USI_0000 USER INFO 0000: The recorder is ready for operation; ; ; ; ; ; //------------------------------------------------------------------- USI_0001 ERROR 0001: The recorder is in test operation - Exposure is not possible; Set the Runtime_test_selector to zero; ; ; ; ; //------------------------------------------------------------------- USI_0800 ERROR 0800: The recorder hardware is defective; The backplane touch memory is defective; ; Note the error number and notify the Service Department; Check the contact of the touch memory module in the backplane; ; //------------------------------------------------------------------- USI_0801 ERROR 0801: The inserted disk is not a system disk for this recorder; The serial number on the inserted disk does not match the serial number of the recorder; ; Insert the disk belonging to the recorder or the backup disk. Create a system disk from a new recorder disk (see the SignaSetter Operation Manual, Installation chapter); ; ; //------------------------------------------------------------------- USI_0802 ERROR 0802: The graphic display could not be initialized; The graphic display files could not be loaded from the recorder disk; ; The data on the recorder disk may have been destroyed - Insert the backup disk of the recorder and then create a system disk (see the SignaSetter Operation Manual, Installation chapter); Check the recorder disk, the disk drive and the main controller of the recorder; ; //------------------------------------------------------------------- USI_0803 ERROR 0803: The material collecting unit (take-up cassette or connected online device) is not selected; The material collecting unit and the parameters of the recorder are different; ; The data on the recorder disk may have been destroyed - Insert the backup disk of the recorder and then create a system disk (see the SignaSetter Operation Manual, Installation chapter); Check the parameters for each used material collecting unit (take-up cassette or connected online device) - When exchanging disks, duplicate the backup disk; ; //------------------------------------------------------------------- USI_0804 ERROR 0804: The supply cassette is not inserted; The supply cassette is not inserted or the touch memory of the supply cassette has a faulty contact or is defective; ; Insert the supply cassette into the input cassette compartment - The supply cassette symbol must appear on the graphic display; Insert the supply cassette into the recorder, check and adjust the touch memory or, if necessary, replace the touch memory (then initialize the supply cassette); ; //------------------------------------------------------------------- USI_0805 ERROR 0805: The take-up cassette is not inserted; The take-up cassette is not inserted or the recognition switch for the take-up cassette is defective; ; Insert the take-up cassette into the recorder; Insert the take-up cassette into the recorder or check the recognition switch for the take-up cassette; ; //------------------------------------------------------------------- USI_0806 ERROR 0806: An error has occurred while advancing the material; The position of the material in the recorder could not be correctly determined; ; Press the error correction button; Check the material advancing mechanics and sensors; ; //------------------------------------------------------------------- USI_0807 ERROR 0807: The take-up cassette has not been emptied; The take-up cassette has not been emptied or the recognition switch for the output cassette is defective; ; Empty the take-up cassette and then insert the empty take-up cassette in the recorder; Insert the empty take-up cassette in the recorder or check the recognition switch for the take-up cassette; ; //------------------------------------------------------------------- USI_0808 ERROR 0808: Advancing the material in the material collecting unit (take-up cassette or connected online device) is not possible because the collecting unit is not ready; The material collecting unit is not ready; ; The take-up cassette is missing or the connected online device is not switched on; The take-up cassette is missing, the recognition switch for the output cassette is defective, the used online device is not connected correctly or the parameters for the material collecting unit are incorrect; ; //------------------------------------------------------------------- USI_0809 ERROR 0809: An error in the cutting device of the recorder has occurred; The switch or the motor of the cutting device is defective - the cutting knife does not reach its end position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the cutting device and the associated control electronics; ; //------------------------------------------------------------------- USI_080A ERROR 080A: The supply cassette is empty; ; ; Insert the filled supply cassette into the supply cassette compartment; ; ; //------------------------------------------------------------------- USI_080B ERROR 080B: An internal data record error has occurred; An error concerning the internal ID-REPLY data record has occurred; ; The data on the recorder disk may have been destroyed - Insert the backup disk of the recorder and then create a system disk (see the SignaSetter Operation Manual, Installation chapter); Check the recorder disk, the disk drive and the main controller of the recorder - When exchanging the disks, duplicate the backup disk; ; //------------------------------------------------------------------- USI_080C ERROR 080C: An external data record error has occurred; An error concerning the external ID-REPLY data record has occurred; ; Replace the software of the external device (OLP). If there is no change, note the error number and notify the Service Department; Check the connection to the external device and, if necessary, replace the software of the external device (OLP); ; //------------------------------------------------------------------- USI_080D ERROR 080D: An internal error has occurred; ; ; Note the error number and notify the Service Department; ; ; //------------------------------------------------------------------- USI_080E ERROR 080E: An error in the automatic recognition of the material position and width has occurred; The optics carriage could not be moved to the measuring position for the right-hand material edge; ; Note the error number and notify the Service Department; Compare the SlowScan configuration parameters of the recorder with those in the manual. If the automatic material position and width recognition issues the incorrect values anyway, check the sensors of the material recognition; ; //------------------------------------------------------------------- USI_080F ERROR 080F: The online developer is not switched on; The online developer is not switched on or a problem with the associated interface signal has occurred; ; Switch on the online developer; Check the online interface: can the signal of the switched-on online device be measured on the recorder and does the appropriate recorder hardware work correctly; ; //------------------------------------------------------------------- USI_0810 ERROR 0810: The online developer is not ready; The online developer is not ready or a problem with the associated interface signal has occurred; ; Wait until the online developer has processed the last job and switches to the READY state; Check the online interface: can the signal of the READY online device be measured on the recorder and does the appropriate recorder hardware work correctly; ; //------------------------------------------------------------------- USI_0811 ERROR 0811: The online developer is not connected to the online recorder interface; The online developer is not connected to the online recorder interface or a problem with the associated interface signal has occurred; ; Connect the online developer to the online recorder interface; Check the online interface: can the signal of the connected online device be measured on the recorder and does the appropriate recorder hardware work correctly; ; //------------------------------------------------------------------- USI_081D ERROR 081D: The recorder could not be initialized; The files from the recorder disk could not be loaded; ; The data on the recorder disk may have been destroyed - Insert the backup disk of the recorder and then create a system disk (see the SignaSetter Operation Manual, Installation chapter); Check the recorder disk, the disk drive and the main controller of the recorder - When exchanging disks, duplicate the backup disk; ; //------------------------------------------------------------------- USI_081F ERROR 081F: The supply cassette does not belong to this recorder; The serial number saved on the supply cassette does not match the serial number of the recorder; ; Insert the input cassette belonging to the recorder or adapt the supply cassette to this recorder (see "Initializing the supply cassette"); ; ; //------------------------------------------------------------------- USI_0820 ERROR 0820: Remove the material from the mould; ; ; Please remove the material manually using the friction wheel of the supply cassette.; ; ; //------------------------------------------------------------------- // Shutter
//------------------------------------------------------------------- USI_0830 ERROR 0830: Timeout at the shutter unit; CAN Timeout MC-BEAM - shutter; ; Press the error correction button. Occurs the error again, notify the Service Department; Use the CAN bus monitor to check the function of MC-BEAM (shutter, focus, aperture, filter). Check data cable and power supply; ; //------------------------------------------------------------------- USI_0831 ERROR 0831: An internal error has occurred; Internal parameter error at the shutter unit; ;
Switch off and on again the machine. Occurs the error again, notify the Service Department; Occurs the error again after switching off and on again, notify the Service Department and reinstall the software;
; //------------------------------------------------------------------- USI_083f ERROR 083f: A shutter error has occurred; The reference of the shutter unit has not been reached; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the shutter, the switch and the MC beam node; ; //------------------------------------------------------------------- USI_0842 ERROR 0842: A shutter error has occurred; The shutter could not be moved into the reference position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the shutter, the switch and the MC beam node; ; //------------------------------------------------------------------- USI_0845 ERROR 0845: A cutting error has occurred; The material is running out. The material remaining in the mould is too short - it cannot be cut; ; Press the error correction button; ; ; //------------------------------------------------------------------- USI_0846 ERROR 0846: The take-up cassette has not been emptied; The take-up cassette has not been emptied or the recognition switch for the take-up cassette is defective; ; Empty the take-up cassette and press the error correction button; Insert the empty take-up cassette in the recorder or check the recognition switch for the take-up cassette; ; //------------------------------------------------------------------- USI_0847 ERROR 0847: A cutting error has occurred; The take-up cassette is not present; ; Press the error correction button; ; ; //------------------------------------------------------------------- USI_084c ERROR 084c: A cutting error has occurred; The minimum material advance for cutting has not been attained; The motor cassette has not yet wound up the material!; Press the error correction button; Are the values for parameter PID 12230 or 588 too small?; ; //------------------------------------------------------------------- USI_084e ERROR 084e: An unloading error has occurred; There is material in or above the loop box; ; Press the error correction button; ; ; //------------------------------------------------------------------- USI_084f ERROR 084f: The take-up cassette is not inserted; The take-up cassette is not inserted or the recognition switch for the take-up cassette is defective ; ; Press the error correction button; Insert the output cassette in the recorder or check the recognition switch for the take-up cassette; ; //-------------------------------------------------------------------- // Filter //------------------------------------------------------------------- USI_0850 ERROR 0850: Timeout at the filter unit; CAN Timeout MC-BEAM - filter; ; Press the error correction button. Occurs the error again, notify the Service Department; Use the CAN bus monitor to check the function of MC-BEAM (filter, shutter, aperture). Check data cable and power supply; ; //------------------------------------------------------------------- USI_0851 ERROR 0851: An internal error has occurred; Internal parameter error at the Filter unit; ;
Switch off and on again the machine. Occurs the error again, notify the Service Department; Occurs the error again after switching off and on again, notify the Service Department and reinstall the software;
; //------------------------------------------------------------------- USI_085f ERROR 085f: A filter error has occurred; The filter unexpectedly moved into the zero position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the filter motor, the switch and the MC beam node. The reference switch for the filter seems to be not o.k.; ; //------------------------------------------------------------------- USI_0862 ERROR 0862: A filter error has occurred; The filter could not be moved into the zero position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the filter motor, the switch and the MC beam node. Cannot reach the reference switch for filter; ; //-------------------------------------------------------------------- USI_0863 ERROR 0863: Material jam while transporting the material; The material could not be transported to the desired position. MED_IN_BUF and MED_BY_BUF are active; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the loop-box, CAN-knot ID 7, the switches MED_IN_BUF and MED_BY_BUF and the take up cassette; ; //------------------------------------------------------------------- USI_0864 ERROR 0864: Material jam during initialization; The material could not be initialized; ; Please roll the material back into the supply cassette, (cut straight) and press the error correction button; ; ; //------------------------------------------------------------------- USI_0866 ERROR 0866: Material jam while loading the material; The material could not be loaded; ; Wind up back the material into the supply cassette, (cut straight) and press the error correction button; Check CAN knot ID 3 and switch MED_CUT; ;
//------------------------------------------------------------------- USI_0867 ERROR 0867: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Switch OLB-DETECT not detected. Check switch OLB-DETECT and CAN-knot ID 7; ; //------------------------------------------------------------------- USI_0868 ERROR 0868: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the mechanic of material transport and CAN-knot ID 7; ; //------------------------------------------------------------------- USI_0869 ERROR 0869: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the connection to the OLB and CAN-knot ID 4 and ID 7; ; //------------------------------------------------------------------- USI_086A ERROR 086A: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the connection to the OLB and CAN-knot ID 4 and ID 7; ; //------------------------------------------------------------------- USI_086B ERROR 086B: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the mechanic of material transport and CAN-knot ID 3; ; //------------------------------------------------------------------- USI_086C ERROR 086C: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the mechanic of material transport and CAN-knot ID 3; ; //------------------------------------------------------------------- USI_086D ERROR 086D: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the mechanic of material transport and CAN-knot ID 7; ; //------------------------------------------------------------------- USI_086E ERROR 086E: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the mechanic of material transport and CAN-knot ID 3; ; //------------------------------------------------------------------- USI_086F ERROR 086F: Material jam while transporting the material; The material could not be transported to the desired position; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the loop-box, CAN-knot ID 7, the switches MED_IN_BUF and MED_BY_BUF and the OLB; ;
//------------------------------------------------------------------- // Blende / Aperture
//------------------------------------------------------------------- USI_0870 ERROR 0870: Timeout at the aperture unit; CAN Timeout MC-BEAM - aperture; ; Press the error correction button. Occurs the error again, notify the Service Department; Use the CAN bus monitor to check the function of MC-BEAM (aperture, shutter, filter). Check data cable and power supply; ; //------------------------------------------------------------------- USI_0871 ERROR 0871: Software error: Aperture unit; Internal parameter error at the aperture unit; ;
Switch off and on again the machine. Occurs the error again, notify the Service Department; Occurs the error again after switching off and on again, notify the Service Department and reinstall the software;
; //------------------------------------------------------------------- USI_087f ERROR 087f: An aperture error has occurred; The reference switch of the aperture unit is not o.k.; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the aperture motor, the switch and the MC beam node. The reference switch for the aperture seems to be not o.k.; ; //------------------------------------------------------------------- USI_0882 ERROR 0882: An aperture error has occurred; The aperture could not be moved into the zero position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the aperture motor, the switch and the MC beam node. Cannot reach the aperture reference switch; ; //------------------------------------------------------------------- USI_0880 ERROR 0880: The supply of material in the supply cassette is running out; The supply of material in the supply cassette is less than 10% of the maximum filling level; ; Preparations for filling the supply cassette should be made; ; ; //------------------------------------------------------------------- USI_0881 ERROR 0881: The take-up cassette is nearly full; The filling level of the take-up cassette is more than 90% of the maximum capacity; ; Preparations for emptying the take-up cassette should be made; ; ; //------------------------------------------------------------------- // Feed MAT IN //------------------------------------------------------------------- USI_0890 ERROR 0890: An internal error has occurred; Timeout at operations with the input roller device CAN MC-MAT IN; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 3; ; //------------------------------------------------------------------- USI_0891 ERROR 0891: An internal error has occurred; Timeout at operations with the input roller device CAN MC-MAT IN; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 3; ; //------------------------------------------------------------------- USI_089f ERROR 089f: An error in the material guide has occurred; An error has occurred at operations with the input roller device CAN MC-MAT IN; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN knot ID 3; ; //------------------------------------------------------------------- USI_08a2 ERROR 08a2: A material guide error has occurred; Material transport with MC-MAT IN: end switch not attained; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of the switches MED_BRI, MED_CUT, MED_BRO and MED_CUT and CAN knot ID 3; ; //-------------------------------------------------------------------- // Feed MAT OUT //------------------------------------------------------------------- USI_08b0 ERROR 08b0: An internal error has occurred; Timeout at operations with the output roller device CAN MC-MAT OUT; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 4; ; //------------------------------------------------------------------- USI_08b1 ERROR 08b1: An internal error has occurred; Timeout at operations with the output roller device CAN MC-MAT OUT; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 4; ; //------------------------------------------------------------------- USI_08bf ERROR 08bf: An error in the material guide has occurred; An error has occurred at operations with the output roller device CAN MC-MAT OUT; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN knot ID 4; ; //------------------------------------------------------------------- USI_08c2 ERROR 08c2: A material guide error has occurred; Material transport with MC-MAT IN: end switch not attained; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of the switches MED_BRI, MED_CUT, MED_BRO and MED_CUT and CAN knot ID 4; ; //-------------------------------------------------------------------- // Punch //------------------------------------------------------------------- USI_08d0 ERROR 08d0: An internal error has occurred; Timeout at operations with the punch device CAN MC-PUNCH/CUT/WIDTH; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 5; ; //------------------------------------------------------------------- USI_08d1 ERROR 08d1: An internal error has occurred; Timeout at operations with the punch device CAN MC-PUNCH/CUT/WIDTH; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 5; ; //------------------------------------------------------------------- USI_08df ERROR 08df: An error in the material guide has occurred; An error has occurred at operations with the punch device CAN MC-PUNCH/CUT/WIDTH; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN knot ID 5; ; //------------------------------------------------------------------- USI_08e2 ERROR 08e2: An error in the recorder hardware has occurred; Switch position for Punch/Cut-device not reached; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN knot ID 5; ; //------------------------------------------------------------------- USI_08e0 ERROR 08e0: A punch error has occurred; The punch could not be moved to the target position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the punch, the switch and the MC-PUNCH/CUT node; ; //------------------------------------------------------------------- USI_08e5 ERROR 08e5: A punching error has occurred; Punch: could not be moved to the zero position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the punch, the switch and the MC-PUNCH/CUT node; ; //------------------------------------------------------------------- USI_08eb ERROR 08eb: Please remove the material from the mould; Due to a previous error, the material must be unloaded; ; Use the friction wheel of the supply cassette to pull back the material until the supply cassette symbol disappears. Then press the error correction button; Reload the material; ; //------------------------------------------------------------------- USI_08ee ERROR 08ee: Exposure outside of the available exposure area; Due to an incorrect parameter, the current exposure is to occur outside of the available exposure area (border area); ; Check the parameters for the current job - Check the setting of the distance from the start of the exposure to the reference punch and, if necessary, set to a valid value; Check the FastScan / SlowScan distance to the reference punch - Check the exposing window and the border area offered by the recorder; ; //------------------------------------------------------------------- // Error while booting the MC nodes //------------------------------------------------------------------- USI_0910 ERROR 0910: Internal CAN transfer error; The parameters could not be transferred to the MC nodes; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the files xy.dat mc.dat, the MC hardware and the CAN bus; ; //------------------------------------------------------------------- USI_0911 ERROR 0911: Internal error - timeout; The parameters could not be transferred to the MC nodes; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the MC nodes and the CAN bus; ; //------------------------------------------------------------------- USI_0912 ERROR 0912: Internal error: MC-XY software not loaded; The program for MC-XY was not loaded; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the MC-XY, CID switches and the CAN bus; ; //------------------------------------------------------------------- USI_0913 ERROR 0913: Internal error: MC-MAT IN software not loaded; The program for MC-MAT IN was not loaded; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the MC-MAT IN, CID switches and the CAN bus; ; //------------------------------------------------------------------- USI_0914 ERROR 0914: Internal error: MC-MAT OUT software not loaded; The program for MC-MAT OUT was not loaded; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the MC-MAT OUT, CID switches and the CAN bus; ; //------------------------------------------------------------------- USI_0915 ERROR 0915: Internal error: MC-BEAM software not loaded; The program for MC-BEAM was not loaded; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the MC-BEAM, CID switches and the CAN bus; ; //------------------------------------------------------------------- USI_0916 ERROR 0916: Internal error: MC-PUNCH/CUT software not loaded; The program for MC-PUNCH/CUT was not loaded; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the MC-PUNCH/CUT, CID switches and the CAN bus; ; //------------------------------------------------------------------- USI_0917 ERROR 0917: Internal error: MC-CAS software not loaded; The program for MC-CAS was not loaded; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the MC-CAS, CID switches and the CAN bus; ; //------------------------------------------------------------------- USI_0918 ERROR 0918: Internal error while loading the software to MC nodes; The program for an MC node was not loaded; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the files xy.bin and mc.bin; ; //------------------------------------------------------------------- USI_0919 ERROR 0919: Internal error - timeout; The software could not be transferred to the MC nodes; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the MC nodes and the CAN bus; ; //------------------------------------------------------------------- USI_091a ERROR 091a: Error while reading the file xy.bin or mc.bin (OS9 error); The file xy.bin or mc.bin could not be found; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the OS9 file system and the directories for xy.bin and mc.bin; ; //------------------------------------------------------------------- USI_091b ERROR 091b: Internal error while loading the software to MC nodes; A MC node is reporting with a CID for which there is no boot file; ; Notify the Service Department; Check the CID switches on the MC nodes and the CAN bus; ; //------------------------------------------------------------------- // Exposure error //------------------------------------------------------------------- USI_091c ERROR 091c: Internal error - timeout; No CEV_POS_OK is coming from MC-XY during the exposure; ; Press the error correction button. Occurs the error again, notify the Service Department; Use the CAN bus monitor to check the function of MC-XY; ; //------------------------------------------------------------------- USI_091e ERROR 091e: Internal error - timeout; MC-XY: communication error for CEV_ORDER_AB. No OK from MC-XY; ; Press the error correction button. Occurs the error again, notify the Service Department; Use the CAN bus monitor to check the function of MC-XY; ; //------------------------------------------------------------------- USI_091f ERROR 091f: Internal error - timeout; MC-XY: communication error for INIT. No ORDER_OK from MC-XY; ; Press the error correction button. Occurs the error again, notify the Service Department; Use the CAN bus monitor to check the function of MC-XY; ; //------------------------------------------------------------------- USI_0930 ERROR 0930: An internal error has occurred; MC-XY: communication error. No ORDER_OK from MC-XY; ; Check if the safety loop is open and press the error correction button. Occurs the error again, notify the Service Department; Check the safety loop and use the CAN bus monitor to check the function of MC-XY; ; //------------------------------------------------------------------- USI_0931 ERROR 0931: An error in the recorderhardware has occurred; ; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the connection to the mirror motor and the XY-CONTROL; ; //------------------------------------------------------------------- USI_0945 ERROR 0945: An error in the recorderhardware has occurred; ; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the connection to the mirror motor and the XY-CONTROL; ; //------------------------------------------------------------------- USI_0946 ERROR 0946: An error in the recorderhardware has occurred; ; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the connection to the mirror motor and the XY-CONTROL; ; //------------------------------------------------------------------- USI_0947 ERROR 0947: An internal error has occurred; ; ; Press the error correction button. Occurs the error again, notify the Service Department; ; ; //------------------------------------------------------------------- USI_0948 ERROR 0948: An internal error has occurred; ; ; Press the error correction button. Occurs the error again, notify the Service Department; ; ; //------------------------------------------------------------------- USI_094d ERROR 094d: An internal error has occurred; ; ; Press the error correction button. Occurs the error again, notify the Service Department; ; ; //------------------------------------------------------------------- // 950 - 970 for combinations from 930-950 //------------------------------------------------------------------- USI_094f ERROR 094f: Exposure error; The start position is too large; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0970 ERROR 0970: Exposure error; MC-XY: The start position is too large; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0971 ERROR 0971: Exposure error; MC-XY: The start position is too small; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0972 ERROR 0972: Exposure error; MC-XY: parameter error; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0973 ERROR 0973: Exposure error; MC-XY: Parameter error; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0974 ERROR 0974: Exposure error; MC-XY: parameter error; ; Please reboot the device. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0975 ERROR 0975: Exposure error; MC-XY: Set position illegal param.; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0976 ERROR 0976: Exposure error; MC-XY: Incorrect exposure parameter; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0977 ERROR 0977: Exposure error; MC-XY: No X reference STOP; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0978 ERROR 0978: Exposure error; MC-XY: Position < 0; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0979 ERROR 0979: Exposure error; MC-XY: Target position < 0; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_097a ERROR 097a: Exposure error; MC-XY: Target position too large; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_097b ERROR 097b: Exposure error; MC-XY: Could not start; ; Parameter error. Press the error correction button. Occurs the error again, notify the Service Department; Check the appropriate PIDs for XY; ; //------------------------------------------------------------------- USI_0981 ERROR 0981: A material guide error has occurred; The loop box door could not be opened; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the loop box, the limit switch and the MC-CAS node; open_door(); //------------------------------------------------------------------- USI_0982 ERROR 0982: A material guide error has occurred; The loop box door could not be closed; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the loop box, the limit switch and the MC-CAS node; close_door(); //------------------------------------------------------------------- USI_0983 ERROR 0983: A material guide error has occurred; After cutting, the material was not pulled far enough into the take-up cassette; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the switch MED_LAST, the take-up cassette and the drive; ; //------------------------------------------------------------------- USI_0990 ERROR 0990: An internal error has occurred; Timeout at operations with the material guide device CAN MC-PUNCH/CUT/WIDTH; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 5; ; //------------------------------------------------------------------- USI_0991 ERROR 0991: An internal error has occurred; Timeout at operations with the material guide device CAN MC-PUNCH/CUT/WIDTH; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 5; ; //------------------------------------------------------------------- USI_099f ERROR 099f: An error in the rcorderhardware has occurred; An error has occurred at operations with the material guide device CAN MC-PUNCH/CUT/WIDTH; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the switches of the material width measurement and CAN knot ID 5; ; //------------------------------------------------------------------- USI_09a2 ERROR 09a2: A material guide error has occurred; The material guide has not reached the limit switches; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the width, the switch and the MC-PUNCH/CUT node; ; //------------------------------------------------------------------- USI_0A00 ERROR 0A00: Communication to the online processor unit is malfunction.; The timeout time for communication has been exceeded.; ; Switch the recorder off and then restart it.; Check the data connection to the online processor unit.; ; //------------------------------------------------------------------- //################################################################### //##### Definitions for ABC-related errors ##### //################################################################### //------------------------------------------------------------------- USI_0A80 ERROR 0A80: A light correction of the recorder optics is not possible; The parameter calculated for the optics filter cannot be set; ; Carry out a light test and a filter test for the inserted material.; ; ; //------------------------------------------------------------------- USI_0A81 ERROR 0A81: A light correction of the recorder optics is not possible; The recorder optics are switched off.; ; The parameters USE OPTIC (PID 530) and USE FILTER (PID 679) must have the value "1"; ; ; //-------------------------------------------------------------------- // Knife //-------------------------------------------------------------------- USI_0a90 ERROR 0a90: An internal error has occurred; Timeout at operations with the Cutting device CAN MC-PUNCH/CUT; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 5; ; //------------------------------------------------------------------- USI_0a91 ERROR 0a91: An internal error has occurred; An error has occurred at operations with the Cutting device CAN MC-PUNCH/CUT; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 5; ; //------------------------------------------------------------------- USI_0a9f ERROR 0a9f: An error in the rcorderhardware has occurred; An error has occurred at operations with the Cutting device CAN MC-PUNCH/CUT; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 5; ; //------------------------------------------------------------------- USI_0aa2 ERROR 0aa2: A cutting device error has occurred; The cutting knife could not be moved to the target. The material could not be cut; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the cutting knife and the MC-PUNCH/CUT node; ; //-------------------------------------------------------------------- USI_0b02 ERROR 0b02: A material guide error has occurred; The material detection switch in the OLP did not reach; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the connection to the OLP, the switch OLB-DETECT, PIDs 12234 and 12235 and the CAN knot ID 4 and ID 7; ; //------------------------------------------------------------------- USI_0b03 ERROR 0b03: A material guide error has occurred; There is still cut material in the take-up cassette or OLB; ; Remove the material from the take-up cassette or OLB and then press the error correction button; ; ; //------------------------------------------------------------------- USI_0b04 ERROR 0b04: A material guide error has occurred; There is still cut material in the take-up cassette or OLB; ; Press the error correction button, occurs the error again notify the service department; Check switch MED_TIGHT and CAN knot ID 4; ; //------------------------------------------------------------------- USI_0b06 ERROR 0b06: A material guide error has occurred; The material could not be tightened; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the switch MED_TIGTH and the MC-MAT OUT node; ; //------------------------------------------------------------------- USI_0b07 ERROR 0b07: A cutting device error has occurred; The cutting knife cannot be moved to the zero position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the cutting knife and the MC-PUNCH/CUT node; ; //------------------------------------------------------------------- USI_0b08 ERROR 0b08: A material guide error has occurred; Switch MED_LAST was not reached during material transport; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the switch MED_LAST, PID 12296 and CAN-knot ID 7; ; //------------------------------------------------------------------- USI_0b09 ERROR 0b09: A material guide error has occurred; There is material remaining in the loop box; ; Press the error correction button. Occurs the error again, call the Service Department; Open the loop box and remove the material if necessary, or check CAN knot ID 7 and switch MED_IN_BUF and MED_BY_BUF; ; //------------------------------------------------------------------- USI_0b0a ERROR 0b0a: A material guide error has occurred; The material was already at the detect switch of the OLP and has slide back out of the OLP; ; Open the OLP and press the error correction button. Occurs the error again, notify the Service Department; Check the connection to the OLP, PIDs 12234 and 12235; ; //------------------------------------------------------------------- USI_0b0b ERROR 0b0b: A material guide error has occurred; A material jam has occurred. The material could not be pulled back; ; Wind back the material into the supply cassette. Then press the error correction button; Check CAN knot ID 3 and switch MED_CUT; ; //------------------------------------------------------------------- USI_0b0c ERROR 0b0c: A material guide error has occurred; Material was not recognized by the material guide. There is no material or the switch is defective.; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the switches of the material guide and the MC-CAS node; ; //------------------------------------------------------------------- USI_0b0d ERROR 0b0d: Internal CAN bus error; Error while transmitting a command to an MC node; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN bus and the software; CAN_WriteEvent(); //------------------------------------------------------------------- USI_0b0e ERROR 0b0e: Internal CAN bus error; Error while transmitting a variable to an MC node; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN bus and the software; CAN_WriteVarReq(); //------------------------------------------------------------------- USI_0b0f ERROR 0b0f: Internal CAN bus error; Error while reading a variable at an MC node; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN bus and the software; CAN_ReadVarReq(); //------------------------------------------------------------------- USI_0b10 ERROR 0b10: Internal CAN bus error; Error while transferring variables to an MC node; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN bus and the software; Error at CAN_DownReq(); //------------------------------------------------------------------- USI_0b11 ERROR 0b11: Internal CAN bus error; Error while reading the switches from an MC node; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN bus; ; //------------------------------------------------------------------- USI_0b12 ERROR 0b12: Internal error: timeout; Timeout error while reading the switches from an MC node; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN bus; ; //------------------------------------------------------------------- USI_0b13 ERROR 0b13: Internal CAN bus error; Error while reading the error message from an MC node; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN bus and the MC nodes; ; //------------------------------------------------------------------- USI_0b14 ERROR 0b14: A material guide error has occurred; The take-up cassette was removed without cutting the material and winding up the remaining material; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the detection switch for the take-up cassette and the MC-MAT OUT node; ; //------------------------------------------------------------------- USI_0b16 ERROR 0b16: Internal CAN bus error; An MC node does not answer during a communication test; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN bus and the MC nodes; ; //------------------------------------------------------------------- USI_0b17 ERROR 0b17: Internal CAN bus or software error; An MC node reports an error that cannot be remedied; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the software, the CAN bus and the MC nodes; ; //------------------------------------------------------------------- USI_0b18 ERROR 0b18: An internal error has occurred; Data file mc.dat or xy.dat could not be read; ; Please reboot the device. Occurs the error again, notify the service department; Check the files xy.dat, mc.dat and the OS9 file system; ; //------------------------------------------------------------------- USI_0b19 ERROR 0b19: Order cancel message from the MC; ; ; ; ; ; //------------------------------------------------------------------- USI_0b1a ERROR 0b1a: Switch Med_tigth did not trip; ; ; ; ; ; //------------------------------------------------------------------- USI_0b1b ERROR 0b1b: A material guide error has occurred; The take-up cassette did not wind up the material after the material had been threaded; ; Remove the take-up cassette and press the error correction button. Occurs the error again, notify the Service Department.; Check the switch MED_IN_BUF and the take-up cassette; ; //------------------------------------------------------------------- USI_0b1c ERROR 0b1c: A material guide error has occurred; No loop is forming in the loop box; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the switch MED_IN_BUF and CAN-knot ID 7; ; //------------------------------------------------------------------- USI_0b1e ERROR 0b1e: A material guide error has occurred; There is material remaining in the loop box; ; Remove the remaining material and press the error correction button; ; ; //------------------------------------------------------------------- USI_0b1f ERROR 0b1f: A material guide error has occurred; Software error: the switch combination and the status are not supported; ; Press the error correction button. Occurs the error again, notify the Service Department.; Software error!; ; //------------------------------------------------------------------- USI_0b20 ERROR 0b20: A material guide error has occurred; The material end did not transport out of the device; ; Remove the take-up cassette and/or the remainder and press the error correction button. Occurs the error again, notify the Service Department.; Check the bearing in the middle of the output roller; ; //------------------------------------------------------------------- USI_0b21 ERROR 0b21: An internal error has occurred; ; ; Press the error correction button. Occurs the error again, notify the Service Department.; ; ; //------------------------------------------------------------------- USI_0b23 ERROR 0b23: A cutting device error has occurred; The cutting knife was initialized and there was material at the cutting knife; ; Press the error correction button. It was switched off during cutting or the limit switches of the cutting knife are defective. There is material remaining in the loop box which has to be removed; ; ; //------------------------------------------------------------------- USI_0b24 ERROR 0b24: A material guide error has occurred; The counter wheel is not working; ; Rewind the material back into the take-up cassette, press the error correction button and feed in the material again. Occurs the error again, notify the Service Department.; Check the counter wheel and PID 591 and CAN knot ID 3; ; //------------------------------------------------------------------- USI_0b25 ERROR 0b25: A material guide error has occurred; Error for switch MED_BRI, there is a material jam or the switch is defective; ; Rewind the material back into the take-up cassette, then press the error correction button. Occurs the error again, notify the Service Department.; Check the switches MED_BRI and MED_ARI and the MC-MAT IN; ; //------------------------------------------------------------------- USI_0b26 ERROR 0b26: Error for switch MED_ARI, there is a material jam or the switch is defective; ; ; Rewind the material back into the take-up cassette, then press the error correction button. Occurs the error again, notify the Service Department.; Check the switches MED_BRI, MED_BRO and MED_ARI and the MC-MAT IN; ; //------------------------------------------------------------------- USI_0b27 ERROR 0b27: Error for switch MED_BRO, there is a material jam or the switch is defective; ; ; Rewind the material back into the take-up cassette, then press the error correction button. Occurs the error again, notify the Service Department.; Check the switches MED_ARI, MED_BRO and MED_CUT and the MC-MAT IN; ; //------------------------------------------------------------------- USI_0b28 ERROR 0b28: Error for switch MED_CUT, there is a material jam or the switch is defective; ; ; Rewind the material back into the take-up cassette, then press the error correction button. Occurs the error again, notify the Service Department.; Check the switches MED_BRO, MED_CUT and MED_LAST and the MC-MAT IN and MC-CAS; ; //------------------------------------------------------------------- USI_0b29 ERROR 0b29: Error at the limit switches of the punches ; Both switches were pressed. The switches must be adjusted!; ; Notify the Service Department.; Check the limit switches of the punches; ; //------------------------------------------------------------------- USI_0b2b ERROR 0b2b: A materialguide error has occurred; There is material remaining in the loop box; ; Please pull out the remaining material and then press the error correction button.; ; ; //------------------------------------------------------------------- USI_0b30 ERROR 0b30: Error at the limit switches of the loop box door; Both switches were pressed. The switches must be adjusted!; ; Notify the Service Department.; Check the limit switches of the loop box door.; ; //------------------------------------------------------------------- USI_0b31 ERROR 0b31: Error at the limit switches of the cutting device; Both switches were pressed. The switches must be adjusted!; ; Notify the Service Department.; Check the limit switches of the cutting device.; ; //------------------------------------------------------------------- USI_0b32 ERROR 0b32: Error for the limit switches of the material guide ; Both switches were pressed. The switches must be adjusted!; ; Notify the Service Department.; Check the limit switches of the material guide.; ; //------------------------------------------------------------------- USI_0c20 ERROR 0c20: An internal error has occurred; Timeout at operations with the cassette device CAN MC-CAS; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 7; ; //------------------------------------------------------------------- USI_0c21 ERROR 0c21: An internal error has occurred; Timeout at operations with the cassette device CAN MC-CAS; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 7; ; //------------------------------------------------------------------- USI_0c2f ERROR 0c2f: An error in the material guide has occurred; An error has occurred at operations with the cassette device CAN MC-CAS; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the CAN knot ID 7; ; //------------------------------------------------------------------- USI_0c32 ERROR 0c32: A materialguide error has occurred; Feed with MC-CASSETTE: Limit switch not reached; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the switch MED-LAST, the take-up cassette and the CAN knot ID 7; ; //------------------------------------------------------------------- USI_0c40 ERROR 0c40: An internal error has occurred; Timeout at operations with the loop-box-device CAN CAS; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 7; ; //------------------------------------------------------------------- USI_0c41 ERROR 0c41: An internal error has occurred; Timeout at operations with the loop-box-device CAN CAS; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 7; ; //------------------------------------------------------------------- USI_0c4f ERROR 0c4f: An error in the recorderhardware has occurred; An error has occurred at operations with the loop-box-device CAN CAS; ; Press the error correction button. Occurs the error again, notify the Service Department; Check the function of CAN knot ID 7; ; //------------------------------------------------------------------- USI_0c52 ERROR 0c52: A error in the loop box has occurred; The material could not be cut transported to the correct position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the loop box and the CAN knot ID 7; ; //------------------------------------------------------------------- USI_0c50 ERROR 0c50: A loop box door error has occurred; The loop box door could not be moved to the target position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the loop box door, the switch and the MC-CAS node; ; //------------------------------------------------------------------- // Focus
//------------------------------------------------------------------- USI_0D00 ERROR 0D00: Timeout at the focus unit; CAN Timeout MC-BEAM - focus; ; Press the error correction button. Occurs the error again, notify the Service Department; Use the CAN bus monitor to check the function of MC-BEAM (focus, aperture, shutter, filter). Check data cable and power supply; ; //------------------------------------------------------------------- USI_0D01 ERROR 0D01: Software error: Focus unit; Internal parameter error at the focus unit; ;
Switch off and on again the machine. Occurs the error again, notify the Service Department; Occurs the error again after switching off and on again, notify the Service Department and reinstall the software;
; //------------------------------------------------------------------- USI_0D0f ERROR 0D0f: A focus error has occurred; The reference switch of the focus unit is not o.k.; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the focus motor, the switch and the MC beam node. The reference switch for the focus seems to be not o.k.; ; //------------------------------------------------------------------- USI_0D12 ERROR 0D12: A focus error has occurred; The focus could not be moved into the zero position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the focus motor, the switch and the MC beam node. Cannot reach the focus reference switch; ; //------------------------------------------------------------------- // Multiplexer
//------------------------------------------------------------------- USI_0D20 ERROR 0D20: Timeout at access to the multiplex unit for aperture and focus; CAN Timeout MC-BEAM - multiplexer; ; Press the error correction button. Occurs the error again, notify the Service Department; Use the CAN bus monitor to check the function of MC-BEAM (multiplexer, aperture, focus). Check data cable and power supply; ; //------------------------------------------------------------------- USI_0D21 ERROR 0D21: An internal error has occurred; Internal parameter error at the multiplexer unit; ;
Switch off and on again the machine. Occurs the error again, notify the Service Department; ;
; //------------------------------------------------------------------- //################################################################### //##### Definitions for communication, OS9 and PHILE ##### //################################################################### USI_1001 ERROR 1001: An internal error has occurred; There is not enough free memory to generate a SPEEDWAY message; ; Note the error number and notify the Service Department; A internal error has occurred; ; //------------------------------------------------------------------- USI_2008 ERROR 2008: The SPEEDWAY connection has been interrupted; Internal error: There is not enough free system memory for SPEEDWAY communication; ; Note the error number and notify the Service Department; Check the revision notes of the current software; rif_open_taxi(); //------------------------------------------------------------------- USI_2009 ERROR 2009: The SPEEDWAY connection has been interrupted; The SPEEDWAY hardware on the RIP interface printed circuit board could not be identified; RCV-FIFO-TEST; An error in the recorder hardware has occurred. Note the error number and notify the Service Department; Replace the RIP interface printed circuit board; rif_open_taxi(); //------------------------------------------------------------------- USI_200A ERROR 200A: An internal error has occurred; A program execution error has occurred; ; Note the error number and notify the Service Department; Check the revision notes of the current software; rif_open_taxi(); //------------------------------------------------------------------- USI_200B ERROR 200B: An internal error has occurred; The system memory for SPEEDWAY communication could not be released; ; Note the error number and notify the Service Department; Check the revision notes of the current software; rif_close_taxi(); //------------------------------------------------------------------- USI_200C ERROR 200C: An internal error has occurred; A program execution error has occurred; ; Note the error number and notify the Service Department; Check the revision notes of the current software and hardware; rif_close_taxi(); //------------------------------------------------------------------- USI_200D ERROR 200D: An internal error has occurred; The transferred channel number is not a valid SpeedWay TAXI channel number; ; Note the error number and notify the Service Department; Check the revision notes of the current software and hardware; switch taxi on LTB; //------------------------------------------------------------------- USI_200E ERROR 200E: An internal error has occurred; The transferred channel number is not a valid SpeedWay TAXI channel number; ; Note the error number and notify the Service Department; Check the revision notes of the current software and hardware; open_taxi; //------------------------------------------------------------------- USI_200F ERROR 200F: An internal error has occurred; The transferred channel number is not a valid SpeedWay TAXI channel number; ; Note the error number and notify the Service Department; Check the revision notes of the current software and hardware; close_taxi; // ################################################################ // ################################################################ // ## Material CONTROL GROUP 0x3000 - 0x3FFF ## // ################################################################ // ################################################################ // ################################################################ // ## EXPOSING CONTROL 0x3000 - 0x30FF ## // ################################################################ //------------------------------------------------------------------- USI_3003 ERROR 3003: An exposure resolution that the recorder cannot set was selected; No associated Material data exists for the selected SlowScan resolution; ; Repeat the exposure using another resolution. Note the error number; Check the application parameters [PID 1] and the static SlowScan parameters; ; // ################################################################ */ // ## Material-CONTROL 0x3100 - 0x31FF ## */ // ################################################################ */ //------------------------------------------------------------------- USI_3100 ERROR 3100: An internal error has occurred; An internal error has occurred while calling up the material control; Initialization of the material transport without initializing the material control; Note the error number and notify the Service Department; Internal error: Notify the Development Department of the error number; Check the initialization sequence (call-up of put_Material); //------------------------------------------------------------------- USI_3101 ERROR 3101: An internal error has occurred; An internal error has occurred while calling up the material control; Material transport function without initializing the material control; Note the error number and notify the Service Department; Internal error: Notify the Development Department of the error number; Check the call-up of put_Material; //------------------------------------------------------------------- USI_3102 ERROR 3102: An internal error has occurred; An internal error has occurred while calling up the material control; Material transport function without initializing the material transport; Note the error number and notify the Service Department; Internal error: Notify the Development Department of the error number; Check the call-up of put_Material; //------------------------------------------------------------------- USI_3103 ERROR 3103: An internal error has occurred; An internal error has occurred while calling up the material control; Incorrect call-up of the material movement software; Note the error number and notify the Service Department; Internal error: Notify the Development Department of the error number; Check the call-up of put_Material; //------------------------------------------------------------------- USI_3104 ERROR 3104: An internal error has occurred; An internal error has occurred while calling up the material control; Incorrect call-up of the material movement software; Note the error number and notify the Service Department; Internal error: Notify the Development Department of the error number; Check the call-up of get_Material; //------------------------------------------------------------------- USI_3105 ERROR 3105: An internal error has occurred; An internal error has occurred while calling up the material control; Incorrect call-up of the material movement software; Note the error number and notify the Service Department; Internal error: Notify the Development Department of the error number; Check the call-up of mes_Material; //------------------------------------------------------------------- USI_3106 ERROR 3106: A parameter error has occurred; The material advance length is larger than the maximum advance length; ; Switch on the recorder with the backup disk; Check the parameters [PID 551] in the static parameters, [PID 1] in the Action parameters; ; //------------------------------------------------------------------- USI_3107 ERROR 3107: A parameter error has occurred; The recorder does not support the type of material that is entered for the material parameter MATERIAL_TYPE; ; The material parameter MATERIAL_TYPE has an incorrect value. The recorder does not support this type of material. Check the material parameters; Check the material parameter MATERIAL_TYPE (PID 1002); ; //------------------------------------------------------------------- USI_3108 ERROR 3108: A parameter error has occurred; The recorder does not support the material thickness that is entered for the material parameter MATERIAL_THICKNESS (in combination with the entered material type); ; The material parameter MATERIAL_THICKNESS (PID 1005) has an incorrect value. The recorder does not support this material thickness for this type of material. Check the material parameters; Check the material parameter MATERIAL_THICKNESS (PID 1005); ; //------------------------------------------------------------------- USI_3109 ERROR 3109: A parameter error has occurred; The recorder does not support the measured material width (in combination with the set material thickness and the entered material type); ; The recorder does not support the measured material width (in combination with the set material thickness and the entered material type). Check the material parameters; Check the measured material width (Material Measure SlowScan, PID 508) as well as the material parameters MATERIAL_TYPE (PID 1002) and MATERIAL_THICKNESS (PID 1005); ; //------------------------------------------------------------------- USI_3110 ERROR 3110: A parameter error has occurred; The VAR_MAT_CONTROL parameters (PIDs 681-700) in the static parameters do not correspond with the defined format or they have been damaged; ; The static parameters for the variable material control are incorrect. Note the error number and notify the Service Department; Check the VAR_MAT_CONTROL parameters (PIDs 681-700) in the static parameters; ; // ################################################################ */ // ## Material_P (PUNCH)0x3200 - 0x32FF ## */ // ################################################################ */ //------------------------------------------------------------------- USI_3200 ERROR 3200: A punch initializing error has occurred; The parameter "punch_configuration" in the static parameters does not match the hardware used; ; Note the error number and notify the Service Department; Check the "punch_configuration" in the static parameters for agreement with the built-in punches. The detection loop of a punch may be defective; ; //------------------------------------------------------------------- USI_3201 ERROR 3201: A punch selection error has occurred; A punch that is not present has been selected. The parameter "punch_action" in the Action parameters does not match the punch configuration used; ; The selected punch is not present. Note the error number and notify the Service Department; Check the setting of the punch configuration on the RIP. Check the parameter "punch_action"; ; //------------------------------------------------------------------- USI_3202 ERROR 3202: A punching error has occurred; The punching mechanism or the punch end stage on the material controller card is defective; ; The recorder punching unit is defective. Note the error number and notify the Service Department; Check the punches and the punching electronics on the material controller; ; // ################################################################ */ // ## Material_E (Material-END)0x3300 - 0x33FF ## */ // ################################################################ */ //------------------------------------------------------------------- USI_3300 ERROR 3300: An error has occurred while transporting the remaining material. The supply cassette is empty; The remaining material could not be transported out of the recorder; ; There is material remaining in the recorder. Manually remove this remaining material (see the SignaSetter Operation Manual, Error Handling section); Check the material controller card and the interrupt logic; ; //------------------------------------------------------------------- USI_3301 ERROR 3301: An error has occurred while transporting the remaining material. The supply cassette is empty; The remaining material could not be transported out of the recorder; ; There is material remaining in the recorder. Manually remove this remaining material (see the SignaSetter Operation Manual, Error Handling section); Check the material controller card, the interrupt logic and the drive for the tightening rolls and the loop rolls; ; //------------------------------------------------------------------- USI_3302 ERROR 3302: An error has occurred while transporting the remaining material. The supply cassette is empty; The remaining material could not be transported out of the recorder; ; There is material remaining in the recorder. Manually remove this remaining material (see the SignaSetter Operation Manual, Error Handling section); Check the material controller card, the interrupt logic, the drive for the tightening rolls and the loop rolls and the DDI-2 electronics; ; //------------------------------------------------------------------- // ################################################################ */ // ## Material_H (Material-MAIN)0x3500 - 0x35FF ## */ // ################################################################ */ //------------------------------------------------------------------- USI_3500 ERROR 3500: A material transport error has occurred; The vacuum valve is defective or is turning in the wrong direction; ; Reload the material after pressing the error correction button; Check the vacuum valve, the valve switch and the material controller; ; //------------------------------------------------------------------- USI_3501 ERROR 3501: A material loading error has occurred; The material end has been detected before loading the material; ; Check the supply cassette and the material in the supply cassette; The material end detector may be defective; ; //------------------------------------------------------------------- USI_3502 ERROR 3502: A material transport error has occurred; The counter of the supply cassette motor has not been interrupted; ; Reload the material after pressing the error correction button; Check the material controller; ; //------------------------------------------------------------------- USI_3503 ERROR 3503: A material transport error has occurred; The counter of the loop roll motor has not been interrupted; ; Reload the material after pressing the error correction button; Check the material controller; ; //------------------------------------------------------------------- USI_3506 ERROR 3506: A material transport error has occurred; The counter of the supply cassette motor has not been interrupted; ; Reload the material after pressing the error correction button; Check the parameters for the supply cassette motor (setting, frequency, material geometry). Check the material controller.; ; //------------------------------------------------------------------- USI_3507 ERROR 3507: A material loading error has occurred; The DDI-2 has not been interrupted; ; Check whether the material jam can be eliminated. Open the recorder and manually eliminate the material jam (see the SignaSetter Operation Manual, Error Handling section). Reload the material after pressing the error correction button; Check the material controller and the DDI-2 unit; ; //------------------------------------------------------------------- USI_3508 ERROR 3508: A material loading error has occurred. The material end has been detected; ; ; Open the recorder and manually eliminate the material jam (if necessary, by pulling it out through the supply cassette compartment, see the SignaSetter Operation Manual, Error Handling section). Insert a filled supply cassette and press the error correction button; The material end has occurred or the material end detector is defective; ; //------------------------------------------------------------------- USI_3509 ERROR 3509: A material loading error has occurred. The material end has been detected; ; ; Open the recorder and manually eliminate the material jam (if necessary, by pulling it out through the supply cassette compartment, see the SignaSetter Operation Manual, Error Handling section). Insert a filled supply cassette and press the error correction button; The material end has occurred or the material end detector is defective; ; //------------------------------------------------------------------- USI_350A ERROR 350A: A material loading error has occurred. A material jam has occurred; ; ; Check whether the material jam can be eliminated. Open the recorder and manually eliminate the material jam (see the SignaSetter Operation Manual, Error Handling section). Reload the material after pressing the error correction button; Check the supply cassette, the loading stage, the retainer, the tighten rolls, the punches and the material controller; ; //------------------------------------------------------------------- USI_350B ERROR 350B: A material loading error has occurred. A material jam has occurred; ; ; Check whether the material jam can be eliminated. Open the recorder and manually eliminate the material jam (see the SignaSetter Operation Manual, Error Handling section). Reload the material after pressing the error correction button; Check the material controller; ; //------------------------------------------------------------------- USI_350C ERROR 350C: A loading error has occurred. There is material remaining in the recess of the recorder. The material end has been detected; ; ; Open the recorder and manually eliminate the material jam (if necessary, by pulling it out through the supply cassette compartment, see the SignaSetter Operation Manual, Error Handling section). Insert a filled supply cassette and press the error correction button; The material end has occurred or the material end detector is defective; ; //------------------------------------------------------------------- USI_350D ERROR 350D: An unloading error has occurred; The counter of the supply cassette motor was unexpectedly interrupted; ; Reload the material after pressing the error correction button; Check the parameters for the supply motor (current, frequency, setting, material geometry) and the material controller.; ; //------------------------------------------------------------------- USI_350E ERROR 350E: An unloading error has occurred; A timeout was triggered during unloading; ; Check the material in the supply cassette. Reload the material after pressing the error correction button; Check the parameters for the supply motor (current, frequency, setting, material geometry) and the material controller; ; //------------------------------------------------------------------- USI_350F ERROR 350F: A cutting error has occurred; Both limit switches detect the cutting knife simultaneously; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the cutting device and the material controller; ; //------------------------------------------------------------------- USI_3510 ERROR 3510: A cutting error has occurred; The cutting knife does not move out of the end position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the cutting device and the material controller; ; //------------------------------------------------------------------- USI_3511 ERROR 3511: A cutting error has occurred; The cutting knife is not in the end position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the cutting device and the material controller; ; //------------------------------------------------------------------- USI_3512 ERROR 3512: A cutting error has occurred; A timeout was triggered during cutting; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the cutting device and the material controller; ; //------------------------------------------------------------------- USI_3515 ERROR 3515: A material advance error has occurred. A material jam has occurred; The material advance monitor reports a malfunction; ; Check whether the material jam can be eliminated. Open the recorder and manually eliminate the material jam (see the SignaSetter Operation Manual, Error Handling section). Reload the material after pressing the error correction button; Check the parameters for the material advance (current, frequency, setting, material geometry) as well as the retainers, the tighten rolls, and the material controller; ; //------------------------------------------------------------------- USI_3516 ERROR 3516: A material advance error has occurred. A material jam has occurred in the film exit unit; The loop monitor reports a malfunction; ; Check whether the material jam can be eliminated. Open the recorder and manually eliminate the material jam (see the SignaSetter Operation Manual, Error Handling section). Reload the material after pressing the error correction button; Check the parameters for the material advance (current, frequency, setting, material geometry) as well as the retainers, the tighten rolls, the loop rolls and the material controller; ; //------------------------------------------------------------------- USI_4006 ERROR 4006: The electronics door and the side or upper cover plate are not closed; The safety circuit reports that the electronics door or the side or upper cover plate is open; ; Close the electronics door or the side or upper cover plate. Then press the error correction button; Check the function of the safety circuit; ; //------------------------------------------------------------------- // ################################################################ */ // ## Material-CONTROL SW 0x3600 - 0x36FF ## */ // ################################################################ */ //------------------------------------------------------------------- USI_3600 ERROR 3600: An internal error has occurred; An internal error has occurred while transferring the parameters; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; Air_control, incorrect parameter; //------------------------------------------------------------------- USI_3601 ERROR 3601: An internal error has occurred; An internal error has occurred while transferring the parameters; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; Prepare_material, incorrect parameter; //------------------------------------------------------------------- USI_3602 ERROR 3602: An internal error has occurred; An internal error has occurred while transferring the parameters; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; start ramp (Material), incorrect parameter; //------------------------------------------------------------------- //################################################################### //### Errors in the Touch Memories ### //###################################################################// USI_6000 ERROR 6000: An error has occurred while accessing the permanent memory of the supply cassette; A hardware error has occurred in the serial communication with the touch memory of the supply cassette; ; The recorder hardware is defective. Note the error number and notify the Service Department; The hardware error is on the main controller or in the wiring of the touch memory; ; //------------------------------------------------------------------- USI_6001 ERROR 6001: An error has occurred while accessing the permanent memory of the supply cassette; A CRC error has occurred while writing or reading the touch memory of the supply cassette; ; Note the error number and notify the Service Department; Check the touch memory of the supply cassette; ; //------------------------------------------------------------------- USI_6002 ERROR 6002: An internal error has occurred while accessing the permanent memory of the supply cassette; A parameter error has occurred while accessing the touch memory of the supply cassette; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_6003 ERROR 6003: A permanent memory module is missing in the recorder; The second touch memory in the backplane is missing or has no contact; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the contact between the second touch memory and the socket or install the second touch memory; ; //------------------------------------------------------------------- USI_6004 ERROR 6004: The supply cassette is not inserted; The supply cassette is not inserted or there is no contact between the touch memory and the socket; ; Insert the supply cassette (the cassette symbol then appears in the display). Then press the error correction button; Check the touch memories. There may be contact problems with the touch memory socket; ; //------------------------------------------------------------------- USI_6005 ERROR 6005: An internal error has occurred while accessing the permanent memories; A parameter error has occurred while accessing the touch memories; Error in the touch memory contents; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_6006 ERROR 6006: An internal error has occurred while accessing the permanent memories; A parameter error has occurred while accessing the touch memories; Too many bytes for the touch memory; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_6007 ERROR 6007: An internal error has occurred while accessing the permanent memories; A hardware error has occurred in the serial communication with the touch memories of the backplane; ; The recorder hardware is defective. Note the error number and notify the Service Department; The hardware error is on the main controller or in the writing of the touch memories of the backplane; ; //------------------------------------------------------------------- USI_6008 ERROR 6008: An internal error has occurred while accessing the permanent memories; A CRC error has occurred while writing or reading a touch memory of the backplane; ; Note the error number and notify the Service Department; Check the touch memories of the backplane; ; //------------------------------------------------------------------- USI_6009 ERROR 6009: An internal error has occurred while accessing the permanent memories; A parameter error has occurred while accessing the touch memories of the backplane; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_7000 ERROR 7000: An internal operating system error has occurred; An OS9 error has occurred; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_7001 ERROR 7001: An internal operating system error has occurred; An OS9 error has occurred; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_7002 ERROR 7002: An internal operating system error has occurred; An OS9 error has occurred; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_7003 ERROR 7003: An internal operating system error has occurred; An OS9 error has occurred; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_7004 ERROR 7004: An internal operating system error has occurred; An OS9 error has occurred; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_7005 ERROR 7005: An internal operating system error has occurred; An OS9 error has occurred; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_7006 ERROR 7006: An internal operating system error has occurred; An OS9 error has occurred; ; Note the error number and notify the Service Department; Please notify the Development Department of the error number; ; //------------------------------------------------------------------- USI_7800 ERROR 7800: A disk error has occurred: either the incorrect or no disk has been inserted; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7801 ERROR 7801: A disk error has occurred: the file cannot be opened; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7802 ERROR 7802: A disk error has occurred: the file cannot be found; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7803 ERROR 7803: A disk error has occurred: the file cannot be read; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7804 ERROR 7804: A disk error has occurred: the file cannot be written; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7805 ERROR 7805: A disk error has occurred: the file cannot be created; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7806 ERROR 7806: A disk error has occurred: the file cannot be deleted; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7807 ERROR 7807: A disk error has occurred: the file cannot be renamed; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7808 ERROR 7808: A disk error has occurred: the directory cannot be edited; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_7809 ERROR 7809: A disk error has occurred: the directory cannot be generated; A PHILE error has occurred; ; Insert the recorder-specific disk or the backup disk and restart the recorder; If the error still occurs after an intact disk has been inserted, check the disk drive and the controller; ; //------------------------------------------------------------------- USI_780A ERROR 780A: A disk error has occurred: the disk is write-protected; ; ; Remove the write protection. Then press the error correction button; ; ; //------------------------------------------------------------------- USI_780B ERROR 780B: The inserted disk is not an UPDATE disk; ; ; After pressing the error correction button, insert the UPDATE disk and then restart the UPDATE procedure; ; ; //------------------------------------------------------------------- USI_780C ERROR 780C: The inserted disk is not a recorder system disk; ; ; Insert the recorder system disk and then press the error correction button; ; ; //------------------------------------------------------------------- // CAUTION !!!! Number 7BFF is reserved and must not // be assigned. There is no text for the number in this file //------------------------------------------------------------------- // ################################################################ */ // ## OPTICGROUP0x8100 - 0x81FF ## */ // ################################################################ */ //------------------------------------------------------------------- USI_8100 ERROR 8100: A parameterization error has occurred in the optics unit; The set bias current of the laser diode is larger than the maximum current; ; Installation error: reinstall the recorder software; The maximum diode current in the static parameters is set too low or the bias current on the RIP is set too high.; ; //------------------------------------------------------------------- USI_8101 ERROR 8101: A parameterization error has occurred in the optics unit; The bias current is set too high; ; Carry out and analyze the light test; The bias current of the laser diode is generating more light than is required.; ; //------------------------------------------------------------------- USI_8102 ERROR 8102: A parameterization error has occurred in the optics unit; The modulation current of the laser diode set to maximum is not sufficient to attain the required light value; ; Check the maximum laser current of the recorder - Carry out and analyze the light test; The bias current setting of the RIP is too low or the laser diode is defective. Check the setting of the bias current using the RIP for the correct values. Check the laser diode; ; //------------------------------------------------------------------- USI_8103 ERROR 8103: A parameterization error has occurred in the optics unit; The light value is not in the permitted range; ; Note the error number and notify the Service Department; Check light parameters PID[1101], PID[1151], PID[1201], PID[1251], PID[1301] and PID[1351]; ; //------------------------------------------------------------------- USI_8110 ERROR 8110: An error has occurred in the optics unit of the recorder; The focus stepping motor cannot find the reference position; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the EC controller and the optics head; ; //------------------------------------------------------------------- USI_8111 ERROR 8111: An error has occurred in the optics unit of the recorder; The optics head unit is defective; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the optics head; ; //------------------------------------------------------------------- USI_8112 ERROR 8112: A parameterization error has occurred in the optics unit; The nominal focus position is not in the permitted range; ; Note the error number and notify the Service Department; Check the focus parameters PID[1122], PID[1172], PID[1222], PID[1272], PID[1322] and PID[1372]; ; //------------------------------------------------------------------- USI_8120 ERROR 8120: An error has occurred in the optics unit of the recorder ; The filter stepping motor cannot find the reference position; ; Note the error number and notify the Service Department; Check the EC controller and the optics head; ; //------------------------------------------------------------------- USI_8121 ERROR 8121: A parameterization error has occurred in the optics unit; The filter number is not in the permitted range; ; Note the error number and notify the Service Department; Check the filter parameters; ; //------------------------------------------------------------------- USI_8122 ERROR 8122: A parameterization error has occurred in the optics unit; The number of the shaping element is not in the permitted range; ; Note the error number and notify the Service Department; Check the shaping element parameters; ; //------------------------------------------------------------------- USI_8123 ERROR 8123: A parameterization error has occurred in the optics unit; Measuring the light value is not possible; ; Carry out and analyze the light test; ; ; // ################################################################ */ // ## MIRROR GROUP0x8200 - 0x82FF ## */ // ################################################################ */ //------------------------------------------------------------------- USI_8200 ERROR 8200: An error has occurred in the mirror motor unit; The control of the mirror motor on the EC controller is defective; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the EC controller; ; //------------------------------------------------------------------- USI_8201 ERROR 8201: A parameterization error has occurred in the mirror motor unit; The number of the Hall sensor is not in the permitted range; ; Note the error number and notify the Service Department; Check the parameter Hall Sensor PID[554] in the static parameters; ; //------------------------------------------------------------------- USI_8202 ERROR 8202: An error has occurred in the mirror motor unit; The time monitor reports a timeout while switching the Hall sensor to SOL; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the EC controller and the SOL setting; ; //------------------------------------------------------------------- USI_8203 ERROR 8203: An error has occurred in the mirror motor unit; The time monitor reports a timeout while running up the mirror motor; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the parameters for the Hall sensor, the compressed air and the EC controller; ; //------------------------------------------------------------------- USI_8204 ERROR 8204: An error has occurred in the mirror motor unit; The EC controller is not receiving a SOL signal; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the parameters for light and for the SOL setting (ECC hardware); ; //------------------------------------------------------------------- USI_8205 ERROR 8205: An error has occurred in the mirror motor unit; The compressed air monitor of the mirror motor reports a drop in pressure; ; The recorder hardware is defective. Note the error number and notify the Service Department; Check the compressed air unit and the temperature control on the compressed air unit; ; //------------------------------------------------------------------- USI_8206 ERROR 8206: An error has occurred in the laser modulator unit; The safety circuit of the laser module is not closed, the laser modulator control is defective or the mirror motor is not running at its nominal speed; ; Check whether the hood and the side cover plate are closed; ; ; //------------------------------------------------------------------- USI_A600 WARNING A600: The recorder is in the "Test" operating mode; ; ; This recorder disk is faulty - Insert the backup disk and restart the recorder; The incorrect LCA file was loaded; ; //------------------------------------------------------------------- //################################################################### //##### user interface ##### //################################################################### USI_AC00 WARNING AC00: The selected material is not in the supply cassette; ; ; Check if the incorrect supply cassette is in the supply cassette compartment or whether an incorrect material was selected; ; ; //------------------------------------------------------------------- USI_CC00 USER INFO CC00: Not all image data were processed by the end of the exposure; The time monitor on the RIP interface printed circuit board interrupted the exposure; ; Repeat the exposure because image information may be missing; Check the RIP interface printed circuit board, the Start Of Line and the Feed Control in the recorder; stop_exposure_vlb(); //------------------------------------------------------------------- USI_CC01 USER INFO CC01: The LCA initialization file cannot be read from the disk; The disk is defective or the LCA initialization file is not on the disk; ; Switch the recorder off and switch it on again using the backup disk; Check whether the file is on the disk; rif_download_lca(); //------------------------------------------------------------------- USI_CC02 USER INFO CC02: The recorder hardware and software are incompatible; The LCA initialization file is not compatible with the RIP interface printed circuit board; ; Switch the recorder off and switch it on again using the backup disk; Check the revision notes for the current software and the hardware version of the RIP interface printed circuit board; check_compatibility(); //------------------------------------------------------------------- USI_CC03 USER INFO CC03: The recorder has received an impermissible application parameter from the RIP; The recorder cannot initialize parameter PID 2; ; The application parameter for the FastScan resolution is impermissible. Start the application using new parameters; Check the revision notes for the current software and the hardware version of the RIP interface printed circuit board; rif_set_resolution_parameter(); //------------------------------------------------------------------- USI_CC04 USER INFO CC04: The recorder has received an impermissible application parameter from the RIP; The recorder cannot initialize parameter PID 795; ; The application parameter for the Pixel Expander is impermissible. Start the application using new parameters; Check the revision notes for the current software and the hardware version of the RIP interface printed circuit board; set_rif_expander_parameter(); //------------------------------------------------------------------- USI_CC05 USER INFO CC05: The recorder has received an impermissible application parameter from the RIP; The recorder cannot initialize parameters FS2BOI [PID 8] and FS2EOI [PID 10]; ; The Image Window in the FastScan direction is impermissible. Start the application using new parameters; Check the revision notes for the current software and the hardware version of the RIP interface printed circuit board; rif_set_scan_range_parameter(); //------------------------------------------------------------------- USI_CC06 USER INFO CC06: The recorder has received an impermissible application parameter from the RIP; The recorder cannot initialize parameter FS2BOI [PID 8]; ; The exposure start position of the Image Window in the FastScan direction is impermissible. Start the application using new parameters; Check the revision notes for the current software and the hardware version of the RIP interface printed circuit board; rif_set_scan_offset_parameter(); //------------------------------------------------------------------- USI_CC07 USER INFO CC07: The recorder has received an impermissible application parameter from the RIP; The recorder cannot initialize parameter FS2BOI [PID 8]. The setting for the FastScan resolution [PID 2] is not possible; ; The exposure start position of the Image Window in the FastScan direction is impermissible. Start the application using new parameters; Check the revision notes for the current software and the hardware version of the RIP interface printed circuit board; rif_set_scan_offset_parameter(); //------------------------------------------------------------------- USI_CC08 USER INFO CC08: The recorder has received an impermissible application parameter from the RIP; The recorder cannot initialize parameter the Bias_ON [PID 793]; ; The switching position of Bias ON cannot be parameterized. Start the application using new parameters; Check the revision notes for the current software and the hardware version of the RIP interface printed circuit board; rif_set_bias_on_parameter(); //------------------------------------------------------------------- USI_CC09 USER INFO CC09: The recorder has received an impermissible application parameter from the RIP; The recorder cannot initialize the parameter Mirror Skipping Factor [PID 503]; ; The application parameter Mirror Skipping Factor is impermissible. Start the application using new parameters; Check the revision notes for the current software and the hardware version of the RIP interface printed circuit board; rif_set_mirror_skipping_parameter(); //------------------------------------------------------------------- USI_CC0A USER INFO CC0A: The recorder has an impermissible entry in the static parameters; Parameter SOL_OFFSET_L PID [816] lies outside of the permissible range; ; Insert the backup disk, switch the recorder off and on again; Check parameter SOL_OFFSET_L PID [816] in the static parameters; ; //------------------------------------------------------------------- USI_CC0B USER INFO CC0B: The recorder has an impermissible entry in the static parameters; Parameter SOL_WIDTH_L PID [817] lies outside of the permissible range; ; Insert the backup disk, switch the recorder off and on again; Check parameter SOL_WIDTH_L PID [817] in the static parameters; ; //------------------------------------------------------------------- USI_D000 USER INFO D000: There is no disk in the disk drive; ; ; Insert the recorder-specific disk in the disk drive, switch the recorder off and on again; ; ; //------------------------------------------------------------------- USI_D001 USER INFO D001: The disk in the disk drive is defective or has an incorrect format, such as DD (720KB); ; ; Insert the recorder-specific disk or the backup disk in the disk drive, switch the recorder off and on again; ; ; //------------------------------------------------------------------- USI_D002 USER INFO D002: A maintenance is necessary.; ; ; Please contact your Customer Support Center.;
|