0 = Type INFO
0_UT = Recorder is ready for operating.
1 = Type ERROR
1_UT = Internal error.
1_ST = An error occurred in the program sequence.
1_UH = Note down the error number and inform the service department.
1_SH = Check the modification notes of the current software and hardware.
2 = Type ERROR
2_UT = Internal error.
2_ST = An error occurred in the program sequence.
2_UH = Note down the error number and inform the service department.
2_SH = Check the modification notes of the current software and hardware.
12 = Type ERROR
12_UT = Internal error.
12_ST = Internal communication error.
12_RT = Intertask communication format error.
12_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
12_SH = Note down the error number and inform the R&D department.
12_RH = Queue message format error. To see more details activate error log file.
35 = Type ERROR
35_UT = An error occurred in a database.
35_ST = The specified record is not available.
35_UH = Note down the error number and inform the service department.
35_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
36 = Type ERROR
36_UT = An error occurred in a database.
36_ST = The specified error got a different type.
36_UH = Note down the error number and inform the service department.
36_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
37 = Type ERROR
37_UT = An error occurred in a database.
37_ST = The length of the value of the specified error is to long for the delivered buffer.
37_UH = Note down the error number and inform the service department.
37_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
38 = Type ERROR
38_UT = An error occurred in a database.
38_ST = The length of the buffer of the specified record is to short for the delivered value.
38_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
38_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
40 = Type ERROR
40_UT = An error occurred in a database.
40_ST = The insertion of a record into a database is not possible.
40_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
40_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
41 = Type ERROR
41_UT = An error occurred in the file system.
41_ST = A file could not be opened.
41_RT = The function fopen returned with error.
41_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
41_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
42 = Type ERROR
42_UT = An error occurred in the file system.
42_ST = A file could not be closed.
42_RT = The function fclose returned with error.
42_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
42_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
43 = Type ERROR
43_UT = An error occurred in the file system.
43_ST = A file could not be seeked.
43_RT = The function fseek returned with error.
43_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
43_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
44 = Type ERROR
44_UT = An error occurred in the file system.
44_ST = A file could not be written.
44_RT = The function fwrite returned with error.
44_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
44_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
45 = Type ERROR
45_UT = An error occurred in the file system.
45_ST = A file could not be read.
45_RT = The function fread returned with error.
45_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
45_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
48 = Type ERROR
48_UT = An error occurred while allocating memory.
48_ST = Memory could not be allocated.
48_RT = The function new returned with a null pointer.
48_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
48_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
49 = Type ERROR
49_UT = An error occurred while parsing a source.
49_ST = A syntax error is occurred.
49_RT = A parser detected a syntax error.
49_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
49_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
94 = Type ERROR
94_UT = Internal system error.
94_ST = Error using operating system function.
94_RT = Error spawning task.
94_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
94_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
95 = Type ERROR
95_UT = Internal system error.
95_ST = Error using operating system function.
95_RT = Error deleting task.
95_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
95_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
96 = Type ERROR
96_UT = Internal system error.
96_ST = Error using operating system function.
96_RT = Error allocating memory.
96_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
96_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
96_RH = check comment text if available.
97 = Type ERROR
97_UT = Internal system error.
97_ST = Error using operating system function.
97_RT = Error freeing memory.
97_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
97_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
98 = Type ERROR
98_UT = Internal system error.
98_ST = Error using operating system function.
98_RT = Error creating memory partition.
98_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
98_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
99 = Type ERROR
99_UT = Internal system error.
99_ST = Error in file operation.
99_RT = unexpected end of file.
99_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
99_SH = Reformat device and / or install new software from filebox.
100 = Type ERROR
100_UT = Internal system error.
100_ST = Error in file operation.
100_RT = file error indicator is set.
100_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
100_SH = Reformat device and / or install new software from filebox.
101 = Type ERROR
101_UT = Internal system error.
101_ST = Error in file operation.
101_RT = file status error.
101_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
101_SH = Reformat device and / or install new software from filebox.
102 = Type ERROR
102_UT = Internal system error.
102_ST = Error in file operation.
102_RT = Error getting file number.
102_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
102_SH = Reformat device and / or install new software from filebox.
103 = Type ERROR
103_UT = Internal system error.
103_ST = Error in file operation.
103_RT = Error opening file.
103_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
103_SH = Reformat device and / or install new software from filebox.
104 = Type ERROR
104_UT = Internal system error.
104_ST = Error in file operation.
104_RT = Error closing file.
104_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
104_SH = Reformat device and / or install new software from filebox.
105 = Type ERROR
105_UT = Internal system error.
105_ST = Error in file operation.
105_RT = Error flushing file.
105_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
105_SH = Reformat device and / or install new software from filebox.
106 = Type ERROR
106_UT = Internal system error.
106_ST = Error in file operation.
106_RT = Error getting file position indicator.
106_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
106_SH = Reformat device and / or install new software from filebox.
107 = Type ERROR
107_UT = Internal system error.
107_ST = Error in file operation.
107_RT = Error setting file position indicator.
107_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
107_SH = Reformat device and / or install new software from filebox.
108 = Type ERROR
108_UT = Internal system error.
108_ST = Error in file operation.
108_RT = Error removing file.
108_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
108_SH = Reformat device and / or install new software from filebox.
109 = Type ERROR
109_UT = Internal system error.
109_ST = Error in file operation.
109_RT = Error changing directory.
109_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
109_SH = Reformat device and / or install new software from filebox.
110 = Type ERROR
110_UT = Internal system error.
110_ST = Error in file operation.
110_RT = Error making directory.
110_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
110_SH = Reformat device and / or install new software from filebox.
111 = Type ERROR
111_UT = Internal system error.
111_ST = Error in file operation.
111_RT = Error while printing to file with variable argument list.
111_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
111_SH = Reformat device and / or install new software from filebox.
112 = Type ERROR
112_UT = Internal system error.
112_ST = Error using operating system function.
112_RT = Error creating semaphore.
112_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
112_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
113 = Type ERROR
113_UT = Internal system error.
113_ST = Error using operating system function.
113_RT = Error deleting semaphore.
113_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
113_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
114 = Type ERROR
114_UT = Internal system error.
114_ST = Error using operating system function.
114_RT = Error taking semaphore.
114_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
114_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
115 = Type ERROR
115_UT = Internal system error.
115_ST = Error using operating system function.
115_RT = Error giving semaphore.
115_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
115_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
116 = Type ERROR
116_UT = Internal system error.
116_ST = Error using operating system function.
116_RT = Error creating message queue.
116_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
116_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
117 = Type ERROR
117_UT = Internal system error.
117_ST = Error using operating system function.
117_RT = Error deleting message queue.
117_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
117_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
118 = Type ERROR
118_UT = Internal system error.
118_ST = Error using operating system function.
118_RT = Error sending to message queue.
118_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
118_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
119 = Type ERROR
119_UT = Internal system error.
119_ST = Error using operating system function.
119_RT = Error receiving from message queue.
119_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
119_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
120 = Type ERROR
120_UT = Internal system error.
120_ST = Error using operating system function.
120_RT = Error creating pipe.
120_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
120_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
121 = Type ERROR
121_UT = Internal system error.
121_ST = Error using operating system function.
121_RT = Error creating ring buffer.
121_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 6 of 49
121_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
122 = Type ERROR
122_UT = Internal system error.
122_ST = Error using operating system function.
122_RT = Error deleting ring buffer.
122_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
122_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
123 = Type ERROR
123_UT = Internal system error.
123_ST = Error using operating system function.
123_RT = Error putting to ring buffer.
123_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
123_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
124 = Type ERROR
124_UT = Internal system error.
124_ST = Error using operating system function.
124_RT = Error getting from ring buffer.
124_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
124_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
126 = Type ERROR
126_UT = Internal system error.
126_ST = Error in file operation.
126_RT = Error getting file length.
126_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
126_SH = Reformat device and / or install new software from filebox.
128 = Type ERROR
128_UT = Internal system error.
128_ST = Error in file operation.
128_RT = not enough disk space.
128_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
128_SH = Reformat device and / or install new software from filebox.
129 = Type ERROR
129_UT = Internal system error.
129_ST = Error in filebox.
129_RT = CRC error.
129_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
129_SH = Reformat device and / or install new software from filebox.
130 = Type ERROR
130_UT = Internal system error.
130_ST = Error in filebox.
130_RT = Error in filebox internal structure.
130_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
130_SH = Reformat device and / or install new software from filebox.
133 = Type ERROR
133_UT = Communication error.
133_ST = Speedway communication error.
133_RT = Format error in speedway communication.
133_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
133_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
134 = Type ERROR
134_UT = Communication error.
134_ST = Speedway communication error.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 7 of 49
134_RT = Speedway to Diag time out.
134_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
134_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
135 = Type ERROR
135_UT = Internal system error.
135_ST = Error using operating system function.
135_RT = TFFS error.
135_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
135_SH = Reformat device and / or install new software from filebox.
135_RH = Entfernen Sie den FLASH-Bereich f\u00fcr TFFS vom Service-Terminal.
136 = Type ERROR
136_UT = Internal system error.
136_ST = Error using operating system function.
136_RT = Error initializing dos file system.
136_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
136_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
146 = Type ERROR
146_UT = Internal system error.
146_ST = Internal communication error.
146_RT = Material init first level not allowed jet.
146_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
146_SH = Note down the error number and inform the R&D department.
147 = Type ERROR
147_UT = Internal system error.
147_ST = Internal communication error.
147_RT = Material init second level not allowed jet.
147_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
147_SH = Note down the error number and inform the R&D department.
148 = Type ERROR
148_UT = Internal system error.
148_ST = Internal communication error.
148_RT = Material error correction not allowed jet.
148_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
148_SH = Note down the error number and inform the R&D department.
149 = Type ERROR
149_UT = Internal system error.
149_ST = Internal communication error.
149_RT = Material general prepare not allowed jet.
149_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
149_SH = Note down the error number and inform the R&D department.
150 = Type ERROR
150_UT = Internal system error.
150_ST = Internal communication error.
150_RT = Material general finish not allowed jet.
150_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
150_SH = Note down the error number and inform the R&D department.
151 = Type ERROR
151_UT = Internal system error.
151_ST = Internal communication error.
151_RT = Material general start not allowed jet.
151_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
151_SH = Note down the error number and inform the R&D department.
152 = Type ERROR
152_UT = Internal system error.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 8 of 49
152_ST = Internal communication error.
152_RT = Material general stop not allowed jet.
152_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
152_SH = Note down the error number and inform the R&D department.
153 = Type ERROR
153_UT = Internal system error.
153_ST = Internal communication error.
153_RT = Material general break not allowed jet.
153_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
153_SH = Note down the error number and inform the R&D department.
154 = Type ERROR
154_UT = Internal system error.
154_ST = Internal communication error.
154_RT = Material extended command not allowed jet.
154_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
154_SH = Note down the error number and inform the R&D department.
155 = Type ERROR
155_UT = Internal system error.
155_ST = Error using operating system function.
155_RT = Error reading from file.
155_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
155_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
156 = Type ERROR
156_UT = Internal system error.
156_ST = Error using operating system function.
156_RT = Error writing to file.
156_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
156_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
157 = Type ERROR
157_UT = Internal system error.
157_ST = Error using operating system function.
157_RT = Error in task delay.
157_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
157_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
158 = Type ERROR
158_UT = An error occurred in a database.
158_ST = The erasing of a record out of a database is not possible.
158_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
158_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
163 = Type ERROR
163_UT = Internal system error.
163_ST = Error in file operation.
163_RT = Error getting string from file.
163_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
163_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
164 = Type ERROR
164_UT = Internal system error.
164_ST = Error in file operation.
164_RT = Error putting sting to file.
164_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
164_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 9 of 49
170 = Type ERROR
170_UT = An internal hardware error occurred.
170_ST = FPGA busy error.
170_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
170_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
171 = Type ERROR
171_UT = An internal hardware error occurred.
171_ST = FPGA detection error.
171_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
171_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
172 = Type ERROR
172_UT = An internal hardware error occurred.
172_ST = FPGA initialization error.
172_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
172_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
173 = Type ERROR
173_UT = An internal hardware error occurred.
173_ST = FPGA busy error.
173_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
173_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
174 = Type ERROR
174_UT = An internal hardware error occurred.
174_ST = FPGA frame data error during configuration.
174_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
174_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
175 = Type ERROR
175_UT = An internal hardware error occurred.
175_ST = FPGA length count error.
175_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
175_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
220 = Type ERROR
220_UT = An error occurred in a database.
220_ST = A file which should be copied does not exist.
220_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
220_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
221 = Type ERROR
221_UT = An error occurred in a database.
221_ST = A file could not be deleted.
221_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
221_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
222 = Type ERROR
222_UT = An error occurred in a database.
222_ST = A file could not be copied.
222_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
222_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
223 = Type ERROR
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 10 of 49
223_UT = An error occurred in a database.
223_ST = A directory could not be created.
223_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
223_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
224 = Type ERROR
224_UT = An error occurred while parsing a source.
224_ST = A simple syntax error is occurred.
224_RT = A parser detected a simple syntax error.
224_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
224_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
225 = Type ERROR
225_UT = An error occurred while parsing a source.
225_ST = A serious syntax error is occurred.
225_RT = A parser detected a serious syntax error.
225_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
225_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
234 = Type CRITICAL
234_UT = Internal error.
234_ST = Operating system error.
234_UH = Note down the error number and inform the service department.
234_SH = Check the modification notes of the current software and hardware.
235 = Type CRITICAL
235_UT = Internal error.
235_ST = Operating system error.
235_UH = Note down the error number and inform the service department.
235_SH = Check the modification notes of the current software and hardware.
237 = Type ERROR
237_UT = An internal hardware error occurred.
237_ST = Communication error on the SPI Bus.
237_UH = Note down the error number and inform the service department.
237_SH = Check (replace) the P3C2-CPU Board.
282 = Type ERROR
282_UT = Internal system error.
282_ST = Error in Package.
282_RT = CRC error.
282_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
282_SH = Use another package.
283 = Type ERROR
283_UT = Internal system error.
283_ST = Error in Package.
283_RT = Error in package internal structure.
283_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
283_SH = Use another package.
284 = Type ERROR
284_UT = Internal system error.
284_ST = Error in FPGA box.
284_RT = CRC error.
284_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
284_SH = Reinstall recorder software.
285 = Type ERROR
285_UT = Internal system error.
285_ST = Error in FPGA box.
285_RT = Error in FPGA box internal structure.
285_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
285_SH = Reinstall recorder software.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 11 of 49
293 = Type INFO
293_UT = The current machine type is usable for test purposes only.
293_ST = The current machine type is usable for test purposes only.
293_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
293_SH = Change machine type to valid value.
294 = Type ERROR
294_UT = The current machine type is invalid.
294_ST = The current machine type is invalid.
294_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
294_SH = Change machine type to valid value.
295 = Type ERROR
295_UT = The current machine variation is invalid.
295_ST = The current machine variation is invalid.
295_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
295_SH = Change machine variation to valid value.
313 = Type CRITICAL
313_UT = Internal system error.
313_ST = Operating system error.
313_RT = intConnect error.
313_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
313_SH = Note down the error number and inform the R&D department.
314 = Type ERROR
314_UT = Internal error.
314_ST = Operating system error.
314_RT = ttyDevCreateError.
314_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
314_SH = Note down the error number and inform the R&D department.
319 = Type ERROR
319_UT = An error occurred while parsing a source.
319_ST = A semantics error occurred.
319_RT = A parser detected the semantics error.
319_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
319_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
320 = Type ERROR
320_UT = An error occurred while parsing a source.
320_ST = Simple semantics error.
320_RT = A parser detected the semantics error.
320_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
320_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
321 = Type ERROR
321_UT = An error occurred while parsing a source.
321_ST = Serious semantics error.
321_RT = A parser detected the semantics error.
321_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
321_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
322 = Type INFO
322_UT = Switch off sequence initiated.
322_ST = Normal switch off sequence initiated.
322_UH = The switch off sequence can take long as the current operation will be finished first and all plates will be ejected.
323 = Type INFO
323_UT = Fast switch off sequence initiated.
323_UH = A second switch off command was received. Only data will be saved before switch off.
324 = Type ERROR
324_UT = An error occurred in the parameter database.
324_ST = The parameter configuration file does not exist.
324_RT = The action restore configuration does not find a parameter configuration file.
324_UH = Shutdown and reboot the machine. Then restore the dataset by executing a restore-configuration with the dataset-file
from the PC.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 12 of 49
400 = Type CRITICAL
400_UT = Internal error.
400_ST = Undefined error.
400_RT = BSP error.
400_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
400_SH = Note down the error number. Inform the R&D department.
401 = Type CRITICAL
401_UT = Internal error.
401_ST = Read error.
401_RT = BSP error.
401_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
401_SH = Note down the error number. Inform the R&D department.
402 = Type CRITICAL
402_UT = Internal error.
402_ST = Wrong magic number received with the data.
402_RT = BSP error.
402_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
402_SH = Note down the error number. Inform the R&D department.
403 = Type CRITICAL
403_UT = Internal error.
403_ST = Buffer size error.
403_RT = BSP error.
403_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
403_SH = Note down the error number. Inform the R&D department.
404 = Type CRITICAL
404_UT = Internal error.
404_ST = Checksum error.
404_RT = BSP error.
404_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
404_SH = Note down the error number. Inform the R&D department.
405 = Type CRITICAL
405_UT = Internal error.
405_ST = Error after select() function.
405_RT = BSP error.
405_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
405_SH = Note down the error number. Inform the R&D department.
406 = Type CRITICAL
406_UT = Internal error.
406_ST = select() timeout.
406_RT = BSP error.
406_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
406_SH = Note down the error number. Inform the R&D department.
407 = Type CRITICAL
407_UT = Internal error.
407_ST = Error after ioctl() function.
407_RT = BSP error.
407_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
407_SH = Note down the error number. Inform the R&D department.
408 = Type CRITICAL
408_UT = Internal error.
408_ST = Not enough buffer for download.
408_RT = BSP error.
408_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
408_SH = Note down the error number. Inform the R&D department.
409 = Type CRITICAL
409_UT = Internal error.
409_ST = Illegal baud rate.
409_RT = BSP error.
409_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
409_SH = Note down the error number. Inform the R&D department.
410 = Type CRITICAL
410_UT = Internal error.
410_ST = Not enough FLASH memory.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 13 of 49
410_RT = BSP error.
410_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
410_SH = Note down the error number. Inform the R&D department.
411 = Type CRITICAL
411_UT = Internal error.
411_ST = Unknown FLASH vendor.
411_RT = BSP error.
411_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
411_SH = Note down the error number. Inform the R&D department.
412 = Type CRITICAL
412_UT = Internal error.
412_ST = Unknown FLASH module.
412_RT = BSP error.
412_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
412_SH = Note down the error number. Inform the R&D department.
413 = Type CRITICAL
413_UT = Internal error.
413_ST = Invalid FLASH map.
413_RT = BSP error.
413_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
413_SH = Note down the error number. Inform the R&D department.
414 = Type CRITICAL
414_UT = Internal error.
414_ST = FLASH not ready.
414_RT = BSP error.
414_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
414_SH = Note down the error number. Inform the R&D department.
415 = Type CRITICAL
415_UT = Internal error.
415_ST = Error clearing the FLASH.
415_RT = BSP error.
415_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
415_SH = Note down the error number. Inform the R&D department.
416 = Type CRITICAL
416_UT = Internal error.
416_ST = Error creating the FLASH map.
416_RT = BSP error.
416_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
416_SH = Note down the error number. Inform the R&D department.
417 = Type CRITICAL
417_UT = Internal error.
417_ST = FLASH sector not found in FLASH map.
417_RT = BSP error.
417_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
417_SH = Note down the error number. Inform the R&D department.
418 = Type CRITICAL
418_UT = Internal error.
418_ST = Error clearing a FLASH sector.
418_RT = BSP error.
418_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
418_SH = Note down the error number. Inform the R&D department.
419 = Type CRITICAL
419_UT = Internal error.
419_ST = Error programming the FLASH.
419_RT = BSP error.
419_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
419_SH = Note down the error number. Inform the R&D department.
420 = Type CRITICAL
420_UT = Internal error.
420_ST = Error checking a FLASH sector.
420_RT = BSP error.
420_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
420_SH = Note down the error number. Inform the R&D department.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 14 of 49
421 = Type CRITICAL
421_UT = Internal error.
421_ST = Timeout programming the FLASH.
421_RT = BSP error.
421_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
421_SH = Note down the error number. Inform the R&D department.
422 = Type CRITICAL
422_UT = Internal error.
422_ST = FLASH not ready.
422_RT = BSP error.
422_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
422_SH = Note down the error number. Inform the R&D department.
423 = Type CRITICAL
423_UT = Internal error.
423_ST = Error comparing the FLASH after write operation.
423_RT = BSP error.
423_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
423_SH = Note down the error number. Inform the R&D department.
424 = Type CRITICAL
424_UT = Internal error.
424_ST = Error connecting with an interrupt.
424_RT = BSP error.
424_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
424_SH = Note down the error number. Inform the R&D department.
425 = Type CRITICAL
425_UT = Internal error.
425_ST = Error activating an interrupt.
425_RT = BSP error.
425_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
425_SH = Note down the error number. Inform the R&D department.
426 = Type CRITICAL
426_UT = Internal error.
426_ST = Out of init error memory.
426_RT = BSP error.
426_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
426_SH = Note down the error number. Inform the R&D department.
427 = Type CRITICAL
427_UT = Internal error.
427_ST = Error initializing the hardware.
427_RT = BSP error.
427_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
427_SH = Note down the error number. Inform the R&D department.
428 = Type CRITICAL
428_UT = Internal error.
428_ST = Error reading from FLASH.
428_RT = BSP error.
428_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
428_SH = Note down the error number. Inform the R&D department.
429 = Type CRITICAL
429_UT = Internal error.
429_ST = Error writing to FLASH.
429_RT = BSP error.
429_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
429_SH = Note down the error number. Inform the R&D department.
430 = Type CRITICAL
430_UT = Internal error.
430_ST = Error after open() function.
430_RT = BSP error.
430_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
430_SH = Note down the error number. Inform the R&D department.
431 = Type CRITICAL
431_UT = Internal error.
431_ST = Error after close() function.
431_RT = BSP error.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 15 of 49
431_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and inform the service.
431_SH = Note down the error number. Inform the R&D department.
440 = Type ERROR
440_UT = Internal system error.
440_ST = Error using operating system function.
440_RT = Error creating watchdog.
440_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
440_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
441 = Type ERROR
441_UT = Internal system error.
441_ST = Error using operating system function.
441_RT = Error deleting watchdog.
441_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
441_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
442 = Type ERROR
442_UT = Internal system error.
442_ST = Error using operating system function.
442_RT = Error starting watchdog.
442_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
442_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
443 = Type ERROR
443_UT = Internal system error.
443_ST = Error using operating system function.
443_RT = Error canceling watchdog.
443_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
443_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3001 = Type CRITICAL
3001_UT = The ventilator for the central electronics is defective! Forcing power off of the recorder!
3001_ST = Electronics ventilator monitor reports an error. You cannot continue operation. Powering down the recorder!
3001_UH = Restart the recorder. If the error recurs, leave the device switched off, note the error number and pass it on to the
responsible service technician.
3001_SH = You may not operate the recorder if the electronics ventilator is defective. If you do, this may damage the electronics
permanently.
3002 = Type ERROR
3002_UT = Wrong Bacher punch configuration!
3002_ST = Bacher Configuration parameter (PID 21958) is wrong. The bit map of the Bacher Configuration (PID 21958) must be a
subset of the bit map of the Punch Configuration (PID 766).
3002_UH = Perform the Restore configuration function of the recorder GUI. If the error occurs again, note the error number and
inform the service personnel.
3002_SH = Re-enter the punch system via the recorder GUI and restart the recorder. If the error continues to occur, check the two
specified parameter values manually.
3003 = Type INFO
3003_UT = The ventilator of the air filter is not working. There will be a loss of recorder quality due to dirty mirrors if this error
occurs over a longer period of time.
3003_ST = The ventilator of the air filter is not rotating or the phase sequence sensor is defective.
3003_UH = Restart the recorder. If the error continues to occur, note the error number and inform the service personnel.
3003_SH = Check the cables and control of the ventilator and the phase sequence sensor.
3004 = Type INFO
3004_UT = The air filter is used and must be replaced. There will be a loss of recorder quality due to dirty mirrors if this error
occurs over a longer period of time.
3004_ST = The sensor for the air filter reports that the filter is used.
3004_UH = Replace the air filter as soon as possible!
3004_SH = Replace the air filter as soon as possible!
3005 = Type ERROR
3005_UT = Max. output level of the optical head is not enough to image in the selected mode!
3005_ST = Max. output level of the optical head is not enough to image in the selected mode!
3005_UH = Set a finer resolution or use a more sensitive plate!
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 16 of 49
3005_SH = Set a finer resolution or use a more sensitive plate!
3006 = Type ERROR
3006_UT = Could not end an internal function because of a higher-ranking action or error message!
3006_ST = Cannot end an action in the recorder because of a preceding error or power-off function!
3006_UH = Check the error messages. Restart the machine if this error recurs after error correction!
3006_SH = The bug should be fixed after error correction or power-off/power- on of the machine!
3007 = Type ERROR
3007_UT = Punch setting doesn't match punch configuration!
3007_ST = RIP punch action doesn't match punch configuration!
3007_UH = Check the punch setting at the RIP. Restart the RIP if the error recurs.
3007_SH = Check the punch setting at the RIP, switch off and on the RIP and check punch action and punch configuration!
3008 = Type CRITICAL
3008_UT = ATTENTION: Plate lost in device! Do NOT correct error!
3008_ST = A plate was probably lost in the device during initialization. Error correction is illegal in this present state!
3008_UH = Switch off the device by pulling out the power connector and manually remove any lost plate! Switch on the recorder
again only when there is no plate in the device!
3008_SH = Switch off the device by pulling out the power connector and manually remove any lost plate! Switch on the recorder
again only when there is no plate in the device!
3009 = Type ERROR
3009_UT = Internal communication error.
3009_ST = Communication with an internal assembly (e.g. Optic) failed.
3009_UH = Restart the recorder. If the message still occurs, note down the error number and inform the service.
3009_SH = Check the cables and actuation of the optics head and all other MSubs- devices.
3010 = Type ERROR
3010_UT = Internal communication error.
3010_ST = Communication with with the Autoloader failed.
3010_UH = Restart the Recorder. If the message still occurs, note down the error number and inform the service.
3010_SH = Check the cables between Recorder and Autoloader.
3011 = Type ERROR
3011_UT = Error in the slow scan unit.
3011_ST = Could not find resolution for calculation of an imaging ramp.
3012 = Type ERROR
3012_UT = Network addresses (IP addresses) conflict.
3012_ST = The two network addresses of the recorder must not come from the same network.
3014 = Type ERROR
3014_UT = An error occurred in the mirror motor unit.
3014_ST = The time monitor reports timeout during the spin-up phase of the mirror motor.
3014_UH = The recorder hardware is defective. Note down the error number and inform the service department.
3014_SH = Check the mirror motor unit.
3015 = Type ERROR
3015_UT = An error occurred in the mirror motor unit.
3015_ST = The time monitor reports timeout during the spin-down phase of the mirror motor.
3015_UH = The recorder hardware is defective. Note down the error number and inform the service department.
3015_SH = Check the mirror motor unit.
3016 = Type ERROR
3016_UT = An error occurred in the air supply unit.
3016_ST = The air safety switch is not closed.
3016_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3016_SH = Check the air supply unit.
3017 = Type ERROR
3017_UT = An error occurred in the air supply unit.
3017_ST = The mirror air cooler temperature is to high.
3017_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3017_SH = Check the air supply unit.
3018 = Type ERROR
3018_UT = Internal communication error.
3018_ST = Communication error on the I2C-Bus.
3018_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3018_SH = Check connections between P3C2-board and external boards.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 17 of 49
3019 = Type ERROR
3019_UT = An error occurred in the air supply unit.
3019_ST = The air pump did not start.
3019_RT = Timeout while reading vacuum pump sensor on fpga-port.
3019_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3019_SH = Check the air supply unit.
3020 = Type ERROR
3020_UT = An error occurred in the optic unit.
3020_ST = The focus stepping motor cannot find the zero position.
3020_UH = The recorder hardware is defective. Note down the error number and inform the service department.
3020_SH = Check the optic head and focus motor parameters.
3021 = Type ERROR
3021_UT = An error occurred in the optic unit.
3021_ST = The focus stepping motor cannot leave the zero position.
3021_UH = The recorder hardware is defective. Note down the error number and inform the service department.
3021_SH = Check the optic head and focus motor parameters.
3022 = Type ERROR
3022_UT = A parameter set-up error occurred in the optic unit.
3022_ST = The focus position set point is not within the permissible range.
3022_UH = Note down the error number and inform the service department.
3022_SH = Check the focus parameter PID[xxxx].
3023 = Type ERROR
3023_UT = An error occurred in the optic unit.
3023_ST = The filter stepping motor cannot find the zero position.
3023_UH = Note down the error number and inform the service department.
3023_SH = Check the optic head and filter motor parameters.
3024 = Type ERROR
3024_UT = An error occurred in the optic unit.
3024_ST = The filter stepping motor cannot leave the zero position.
3024_UH = The recorder hardware is defective. Note down the error number and inform the service department.
3024_SH = Check the optic head and filter motor parameters.
3025 = Type ERROR
3025_UT = A parameter set-up error occurred in the optic unit.
3025_ST = The filter number is not within the permissible range.
3025_UH = Note down the error number and inform the service department.
3025_SH = Check the filter parameters.
3026 = Type ERROR
3026_UT = A parameter set-up error occurred in the optic unit.
3026_ST = The number of the shaping element is not within the permissible range.
3026_UH = Note down the error number and inform the service department.
3026_SH = Check the shaping element parameters.
3027 = Type ERROR
3027_UT = An error occurred in the optic unit.
3027_ST = The adjust bias current of the laser diode is higher than the maximum current.
3027_UH = Note down the error number and inform the service department.
3027_SH = The maximum diode current in the static parameters is too low, or the laser diode is defective. Check the laser diode.
3028 = Type ERROR
3028_UT = An error occurred in the optic unit.
3028_ST = The maximum bias current of the laser diode is not sufficient to achieve the required light value.
3028_UH = Note down the error number and inform the service department.
3028_SH = The laser diode is defective. Check the laser diode.
3029 = Type ERROR
3029_UT = An error occurred in the optic unit.
3029_ST = The adjusted current of the laser diode is higher than the maximum current.
3029_UH = Note down the error number and inform the service department.
3029_SH = The maximum diode current in the static parameters is too low, or the laser diode is defective. Check the laser diode.
3030 = Type ERROR
3030_UT = A parameter set-up error occurred in the optic unit.
3030_ST = The modulation current of the laser diode set to maximum is not sufficient to achieve the required light value.
3030_UH = Note down the error number and inform the service department.
3030_SH = The laser diode is defective. Check the laser diode.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 18 of 49
3031 = Type ERROR
3031_UT = An error occurred in the optic unit.
3031_ST = The laser diode must be on for the light stabilization.
3031_UH = Note down the error number and inform the service department.
3031_SH = Report the error number to the development department.
3032 = Type ERROR
3032_UT = An error occurred in the optic unit.
3032_ST = The light stabilization must be off.
3032_UH = Note down the error number and inform the service department.
3032_SH = Report the error number to the development department.
3033 = Type ERROR
3033_UT = An error occurred in the optic unit.
3033_ST = Passed value is to high for this function.
3033_UH = Note down the error number and inform the service department.
3033_SH = Report the error number to the development department.
3034 = Type ERROR
3034_UT = An error occurred in the optic unit.
3034_ST = Passed value is to low for this function.
3034_UH = Note down the error number and inform the service department.
3034_SH = Report the error number to the development department.
3050 = Type ERROR
3050_UT = On board device error.
3050_ST = Unable to set mirror power supply (36 V).
3050_RT = Unable to set resolution depended voltage for mirror on MASC-Board (35-38 V).
3050_UH = Note down the error number and inform the service department.
3050_SH = Check the power supply (36 V).
3051 = Type ERROR
3051_UT = An error occurred in the slow scan unit.
3051_ST = The stepper board signals a short circuit, the safety loop is open or power supply (36V) failed.
3051_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3051_SH = Check the safety loop and the power supply (36V).
3052 = Type ERROR
3052_UT = An error occurred in the slow scan unit.
3052_ST = The stepper board signals high temperature.
3052_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3052_SH = Check the safety loop and the power supply (36V).
3053 = Type ERROR
3053_UT = An error occurred in the slow scan unit.
3053_ST = The stepper board signals not ready.
3053_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3053_SH = Check the safety loop and the power supply (36V).
3054 = Type ERROR
3054_UT = An error occurred in the slow scan unit.
3054_ST = The carrier reaches the left limit.
3054_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3054_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3055 = Type ERROR
3055_UT = An error occurred in the slow scan unit.
3055_ST = The carrier reaches the right limit.
3055_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3055_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3056 = Type ERROR
3056_UT = An error occurred in the slow scan unit.
3056_ST = The carrier is moving when it is not allowed.
3056_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 19 of 49
3056_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3057 = Type ERROR
3057_UT = An error occurred in the slow scan unit.
3057_ST = The safety loop is not closed.
3057_UH = Check all open cases and close them.
3057_SH = Check the safety loop and the power supply (24V).
3058 = Type ERROR
3058_UT = An error occurred in the slow scan unit.
3058_ST = An interrupt has occurred when not expected. Interrupt: Stop.
3058_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3058_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3059 = Type ERROR
3059_UT = An error occurred in the slow scan unit.
3059_ST = An interrupt has occurred when not expected. Interrupt: Signal of light barrier has changed.
3059_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3059_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3060 = Type ERROR
3060_UT = An error occurred in the slow scan unit.
3060_ST = An interrupt has occurred when not expected. Interrupt: Destination reached.
3060_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3060_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3061 = Type ERROR
3061_UT = An error occurred in the slow scan unit.
3061_ST = A SlowScan timeout is occurred during finding a position or moving into the light barrier.
3061_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3061_SH = Check the slow scan mechanic, light barrier, connectors and power supply.
3062 = Type ERROR
3062_UT = An error occurred in the slow scan unit.
3062_ST = A valid ramp could not be found.
3062_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3062_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3063 = Type ERROR
3063_UT = An error occurred in the slow scan unit.
3063_ST = A ramp which fits into a specified distance could not be found.
3063_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3063_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3064 = Type ERROR
3064_UT = A parameter error occurred.
3064_ST = The value of a parameter is not valid.
3064_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3064_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3078 = Type ERROR
3078_UT = An internal software error occurred.
3078_ST = An attempt to read an uninitialized ADC device.
3078_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3078_SH = Note down the error number and notify the R&D department.
3078_RH = Read Adc device without first level init.
3088 = Type ERROR
3088_UT = An error occurred while material handling.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 20 of 49
3088_ST = Timeout at build vacuum.
3088_UH = Execute error correction. If the error still occurs, note down the error number and notify the service department.
3088_SH = Check the vacuum pumps, vacuum sensor, vacuum hoses and / or MASC Board.
3089 = Type ERROR
3089_UT = An error occurred while material handling.
3089_ST = Timeout at vacuum off.
3089_UH = Execute error correction. If the error still occurs, note down the error number and notify the service department.
3089_SH = Check the vacuum pump and MASC Board.
3138 = Type ERROR
3138_UT = An error occurred at punch init.
3138_ST = Punch not connected or not configured.
3138_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3138_SH = Check the punch unit, punch connector and parameter punch configuration in static data.
3159 = Type ERROR
3159_UT = An error occurred in the slow scan unit.
3159_ST = The safety loop is not closed.
3159_UH = Check all open cases and close them.
3159_SH = Check the safety loop and the power supply (36V).
3160 = Type ERROR
3160_UT = An error occurred in the slow scan unit.
3160_ST = The carrier reaches the left limit.
3160_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3160_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3161 = Type ERROR
3161_UT = An error occurred in the slow scan unit.
3161_ST = The carrier reaches the right limit.
3161_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3161_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3162 = Type ERROR
3162_UT = An error occurred in the slow scan unit.
3162_ST = The stepper board signals not ready.
3162_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3162_SH = Check the safety loop and the power supply (36V).
3165 = Type ERROR
3165_UT = An error occurred while setting the light intensity.
3165_ST = The BaseIntensity value for the selected resolution of the current job is lower than the adjustable light.
3165_UH = The used light intensity is too low. Check the intensity value for the selected resolution. Perform a FineIntensityTest
and repeat the exposure.
3165_SH = Control the BaseIntensity values for all resolutions and the optic head static parameters. Reboot the system after
parameter changes. If the error still occurs, copy logfile info for further analysis .
3168 = Type ERROR
3168_UT = An error occurred in the slow scan unit.
3168_ST = The feed ramp could not be written.
3168_UH = Note down the error number and inform the service department.
3168_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3169 = Type ERROR
3169_UT = An error occurred in the slow scan unit.
3169_ST = Error while calculating feed ramp data.
3169_UH = Note down the error number and inform the service department.
3169_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3198 = Type ERROR
3198_UT = Not calibrated resolution selected.
3198_ST = The selected resolution is not calibrated. The BaseIntensity parameter for the selected resolution is zero.
3198_UH = The intensity value for the selected resolution is not calibrated. Perform a FineIntensityTest and repeat the exposure.
3198_SH = Perform a FineIntensityTest and repeat the exposure. If the error still occurs, copy logfile info for further analysis.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 21 of 49
3199 = Type ERROR
Уже 2 раза была из-за вылета ремня у мотора slider на барабане
3199_UT = An communication error to the optic head occurred.
3199_ST = The communication to the optic head is broken.
3199_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3199_SH = Reboot the system. If the error still occurs, copy logfile info for further analysis.
3200 = Type ERROR
3200_UT = An communication error to the optic head occurred.
3200_ST = The communication to the optic head is faulty.
3200_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3200_SH = Reboot the system. If the error still occurs, copy logfile info for further analysis.
3201 = Type ERROR
3201_UT = An error occurred in the optichead unit.
3201_ST = The number of gate impulses generated by the Image-Control is out of range.
3201_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3201_SH = Check the cabling and connectors to other PCB's. Reboot the system. If the error still occurs, copy logfile info for
further analysis.
3202 = Type ERROR
3202_UT = An error occurred in the optichead unit.
3202_ST = The temperature of the laser diode did not change after switching on the temperature regulation.
3202_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3202_SH = Change the optichead . Reboot the system. If the error still occurs, copy logfile info for further analysis.
3203 = Type ERROR
3203_UT = An error occurred in the optichead unit.
3203_ST = The temperature of the laser diode is over the maximum allowed temperature.
3203_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3203_SH = Change the optichead . Reboot the system. If the error still occurs, copy logfile info for further analysis.
3204 = Type ERROR
3204_UT = An error occurred in the optichead unit.
3204_ST = A parameter transmitted to the optichead is out of range.
3204_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3204_SH = Reboot the system. If the error still occurs, copy logfile info for further analysis.
3205 = Type ERROR
3205_UT = An error occurred in the optichead unit.
3205_ST = A parameter transmitted to the optichead is out of range.
3205_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3205_SH = Reboot the system. If the error still occurs, copy logfile info for further analysis.
3206 = Type ERROR
3206_UT = An error occurred in the optichead unit.
3206_ST = An error without a defined event has occurred.
3206_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3206_SH = Reboot the system. If the error still occurs, copy logfile info for further analysis.
3207 = Type ERROR
3207_UT = An error occurred in the optichead unit.
3207_ST = The light value on the laser diode with the bias current alone is higher than the value in the application data. This may
be due to an error in the primesetter or a not initialized material data set or an defective optichead.
3207_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3207_SH = If all parameters are correct, change the optichead. Reboot the system. If the error still occurs, copy logfile info for
further analysis.
3208 = Type ERROR
3208_UT = An error occurred in the optichead unit.
3208_ST = The error occurs if you switch on the temperature regulation on the optichead without a regulation device.
3208_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3208_SH = Check the temperature regulation specific parameters of the optichead. Reboot the system. If the error still occurs,
copy logfile info for further analysis.
3209 = Type ERROR
3209_UT = An error occurred in the mirror motor unit.
3209_ST = The mirror phased out during transmission. The mirror is not locked.
3209_RT = The mirror phased out during transmission. The mirror is not locked.
3209_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3209_SH = Check the mirror motor unit.
3211 = Type ERROR
3211_UT = An error occurred in the vacuum unit while material handling.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 22 of 49
3211_ST = The detect vacuum is much too low.
3211_UH = Execute error correction. If the error still occurs, note down the error number and notify the service department.
3211_SH = Check the vacuum pumps, parameter settings, vacuum sensor, vacuum hoses and / or MASC Board.
3212 = Type ERROR
3212_UT = An error occurred while selecting the focus value.
3212_ST = The RIP transmitted resolution is not a element of the recorder resolution table.
3212_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3212_SH = Check the resolution parameter. If the error still occurs, copy logfile info for further analysis.
3213 = Type ERROR
3213_UT = An error occurred in the optic unit.
3213_ST = The calculation of the spotshape value failed.
3213_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3213_SH = Check the optichead parameter. If the error still occurs, copy logfile info for further analysis.
3214 = Type ERROR
3214_UT = An error occurred in the optic unit.
3214_ST = The calculation of the filter value failed.
3214_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3214_SH = Check the optichead parameter. If the error still occurs, copy logfile info for further analysis.
3215 = Type ERROR
3215_UT = An error occurred in the optic unit.
3215_ST = The calculation of the physical focus value failed.
3215_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3215_SH = Check the optichead parameter. If the error still occurs, copy logfile info for further analysis.
3216 = Type ERROR
3216_UT = An error occurred in the optic unit.
3216_ST = The calculation of the logical light value failed.
3216_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3216_SH = Check the optichead parameter. If the error still occurs, copy logfile info for further analysis.
3217 = Type CRITICAL
3217_UT = The safety loop was at least briefly interrupted.
3217_RT = ORL - ERR_SAFETY_LOOP_OPEN
3217_UH = Close all covers of the machine, release the emergency switch and execute an error correction.
3217_SH = Check the safety loop switches and the emergency switches.
3226 = Type ERROR
3226_UT = An error occurred while setting the light intensity.
3226_ST = The BaseIntensity value for the selected resolution of the current job is lower than the adjustable light.
3226_UH = The used light intensity is too low. Check the intensity value for the selected resolution. Perform a FineIntensityTest
and repeat the exposure.
3226_SH = Control the BaseIntensity values for all resolutions and the optic head static parameters. Reboot the system after
parameter changes. If the error still occurs, copy logfile info for further analysis .
3227 = Type ERROR
3227_UT = An error occurred while setting the light intensity.
3227_ST = The BaseIntensity value for the selected resolution of the current job is higher than the adjustable light.
3227_UH = The used light intensity is too high. Check the intensity value for the selected resolution. Perform a FineIntensityTest
and repeat the exposure.
3227_SH = Control the BaseIntensity values for all resolutions and the optic head static parameters. Reboot the system after
parameter changes. If the error still occurs, copy logfile info for further analysis .
3228 = Type ERROR
3228_UT = An error occurred in the optichead unit.
3228_ST = The light value on the laser diode with the modulation current alone is to high . This may be due to an error in the
primesetter or an defective optichead.
3228_UH = Reboot the system. If the error still occurs, note down the error number and inform the service department.
3228_SH = If all parameters are correct, change the optichead. Reboot the system. If the error still occurs, copy logfile info for
further analysis.
3229 = Type CRITICAL
3229_UT = An error occurred in the air supply unit.
3229_ST = The high-water sensor is still active, after water blow-off.
3229_RT = The high-water sensor is still active, after water blow-off.
3229_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3229_SH = Release Water from the air supply unit, and check water sensors in this unit.
3229_RH = Release Water from the air supply unit, and check water sensors in this unit.
3230 = Type CRITICAL
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 23 of 49
3230_UT = An error occurred in the air supply unit.
3230_ST = The high-water sensor is still active, after water blow-off.
3230_RT = The system checker: the high-water sensor is still active, after water blow-off 3 times .
3230_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3230_SH = Release Water from the air supply unit, and check water sensors in this unit.
3230_RH = Release Water from the air supply unit, and check water sensors in this unit.
3238 = Type WAITING
3238_UT = Plate on table missing for load.
3238_ST = Possibly plate detector (on plate table) defect.
3238_UH = Put requested plate on the table.
3238_SH = Check the plate detector (light switch).
3239 = Type ERROR
3239_UT = An error occurred at punch action.
3239_ST = Timeout at punch action (10s) at arrive ls.
3239_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3239_SH = Check the punch unit, punch connector and parameter punch configuration in static data.
3240 = Type ERROR
3240_UT = An error occurred at material transport.
3240_ST = Timeout at drive plate slider to Down-Wait Position (prepare to load).
3240_UH = Execute error correction. If the error still occurs, note down the error number and inform the service.
3240_SH = Check the slider motor, slider encoder, slider strap and slider static parameters.
3241 = Type ERROR
3241_UT = An error occurred at material transport.
3241_ST = Timeout at drive plate slider to Down-Free position (unload plate).
3241_UH = Execute error correction. If the error still occurs, note down the error number and inform the service.
3241_SH = Check the slider motor, slider encoder, slider strap and slider static parameters.
3242 = Type ERROR
3242_UT = An error occurred at material transport.
3242_ST = Timeout at drive plate slider to Up-Unload Position (unload plate or init).
3242_UH = Execute error correction. If the error still occurs, note down the error number and inform the service.
3242_SH = Check the slider motor, slider encoder, slider strap and slider static parameters.
3243 = Type ERROR
3243_UT = An error occurred at material transport.
3243_ST = Timeout at center plate on table.
3243_UH = Execute error correction. If the error still occurs, note down the error number and inform the service.
3243_SH = Check plate table, table motor and sensors. Check table static parameters.
3244 = Type WAITING
3244_UT = Plate on the table is not valid. Measured plate width is different to requested plate.
3244_ST = Plate on the table is not valid. Measured plate width is different to requested plate.
3244_UH = Remove plate from table and insert requested plate.
3244_SH = Remove plate from table and insert requested plate.
3245 = Type ERROR
3245_UT = Inserted plate is not valid. Measured plate length is different to requested plate.
3245_ST = Inserted plate is not valid. Measured plate length is different to requested plate.
3245_UH = Remove plate from table and insert requested plate.
3245_SH = Remove plate from table and insert requested plate.
3246 = Type WAITING
3246_UT = Unexpected plate on table detected. Exposed plate can not be ejected.
3246_ST = Unexpected plate on table detected. Exposed plate can not be ejected.
3246_UH = Remove plate from table and wait for plate eject.
3246_SH = Remove plate from table and wait for plate eject.
3247 = Type ERROR
3247_UT = An error occurred at material transport.
3247_ST = A timeout is occurred during moving the lift into a position. No interrupt occurred.
3247_UH = Execute error correction. If the error still occurs, note down the error number and notify the service department.
3247_SH = Check the cable connections on the backplane.
3248 = Type ERROR
3248_UT = There is no plate at the grip. Loading material isn't possible.
3248_ST = The plate sensor at the grip signals no-plate.
3248_UH = Insert the requested plate correctly.
3248_SH = Check the grip, sensors, power supply and cable connections on the backplane.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 24 of 49
3249 = Type ERROR
3249_UT = An internal hardware error occurred.
3249_ST = The lift stepping motor cannot find it's zero position.
3249_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3249_SH = Check the cable connections on the backplane.
3250 = Type INFO
3250_UT = An internal hardware error occurred. One or more fans at the back-wall don't work.
3250_ST = One or more of the guide fans at the back-wall don't work.
3250_RT = Upper left guide fan is not running.
3250_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3250_SH = Check the cable connections on the backplane.
3251 = Type INFO
3251_UT = An internal hardware error occurred. One or more fans at the back-wall don't work.
3251_ST = One or more of the guide fans at the back-wall don't work.
3251_RT = Upper right guide fan is not running.
3251_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3251_SH = Check the cable connections on the backplane.
3252 = Type INFO
3252_UT = An internal hardware error occurred. One or more fans at the back-wall don't work.
3252_ST = One or more of the guide fans at the back-wall don't work.
3252_RT = Lower left guide fan is not running.
3252_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3252_SH = Check the cable connections on the backplane.
3253 = Type INFO
3253_UT = An internal hardware error occurred. One or more fans at the back-wall don't work.
3253_ST = One or more of the guide fans at the back-wall don't work.
3253_RT = Lower right guide fan is not running.
3253_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3253_SH = Check the cable connections on the backplane.
3254 = Type ERROR
3254_UT = The safety loop is open.
3254_ST = Error while starting the lift. The safety loop is open.
3254_UH = Close all covers of the machine and press the error correction key.
3254_SH = Check the safety loop and the power supply (24V).
3255 = Type ERROR
3255_UT = An internal hardware error occurred.
3255_ST = Turning the grip into the 5 deg. position failed.
3255_RT = The 0 deg. sensor in the grip is still active.
3255_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3255_SH = Check Plate, grip position and grip 0 deg. sensor.
3256 = Type ERROR
3256_UT = An internal hardware error occurred.
3256_ST = A timeout is occurred.
3256_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3256_SH = Check the cable connections on the backplane.
3258 = Type ERROR
3258_UT = Plate position in lift is not valid for unloading.
3258_ST = Inserted plate is not valid. Measured plate length is different to requested plate.
3258_UH = Execute error correction. If the error still occurs, note down the error number and notify the service department.
3258_SH = Check the plate length detector (light barriers switch) and lift position.
3259 = Type ERROR
3259_UT = An error occurred at material transport.
3259_ST = Moving the unload flaps failed. A timeout error occurred .
3259_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3259_SH = Check the unload flaps, sensors, power supply and cable connections on the backplane.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 25 of 49
3260 = Type ERROR
3260_UT = An error occurred at material transport.
3260_ST = Moving the flaps failed. They didn't reach their in-or-out target position.
3260_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3260_SH = Check the unload flaps, sensors, power supply and cable connections on the backplane.
3261 = Type ERROR
3261_UT = An error occurred at material transport.
3261_ST = Grip motor didn't reach the correct angle.
3261_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3261_SH = Check lift position, grip mechanic and cable connections on the backplane.
3262 = Type ERROR
3262_UT = An error occurred at material transport.
3262_ST = Lift didn't reach it's set position. Maybe stopped by a sporadic interrupt.
3262_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3262_SH = Check the cable connections on the backplane.
3263 = Type ERROR
3263_UT = An error occurred at material transport.
3263_ST = Moving the lift isn't possible because the flaps stays in the path.
3263_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3263_SH = Check the unload flaps, sensors, power supply and cable connections on the backplane.
3264 = Type ERROR
3264_UT = An error occurred at material transport.
3264_ST = Moving the lift isn't possible because the grip unit is in horizontal position.
3264_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3264_SH = Check lift position, grip mechanic and cable connections on the backplane.
3265 = Type ERROR
3265_UT = An error occurred at material transport.
3265_ST = There are no valid parameter available.
3265_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3265_SH = Not correctly initialized system. Maybe error occurred by using unattended test functions .
3266 = Type ERROR
3266_UT = An error occurred at material transport.
3266_ST = Lift lost it's position. Lower reference light-barrier shows a position error bigger than 1.2mm .
3266_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3266_SH = Check lift position, grip mechanic and cable connections on the backplane.
3267 = Type ERROR
3267_UT = Material Length isn't possible to load.
3267_ST = It isn't possible to move the lift into the calculated load position for this material length.
3267_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3267_SH = Check the parameters of the lift/grip system.
3269 = Type ERROR
3269_UT = An error occurred at material transport.
3269_ST = This operation isn't possible at this time because the system wasn't initialized correctly .
3269_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3269_SH = Not correctly initialized system. Maybe error occurred by using unattended test functions .
3270 = Type ERROR
3270_UT = The set lift position is out of range.
3270_ST = It isn't possible to move the lift into the calculated load position for this material length .
3270_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3270_SH = Check the parameters of the lift/grip system.
3271 = Type ERROR
3271_UT = An error occurred at material transport.
3271_ST = There are no valid parameter available .
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 26 of 49
3271_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3271_SH = Check the parameters of the lift/grip system.
3272 = Type ERROR
3272_UT = An error occurred at material transport.
3272_ST = Initializing of the lift not possible - maybe the grip is still under the hooks in the indrum .
3272_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3272_SH = Check lift position, grip mechanic and cable connections on the backplane.
3274 = Type ERROR
3274_UT = An error occurred in the lift and grip unit.
3274_ST = The stepper board signals not ready.
3274_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3274_SH = Check the safety loop and the power supply (24V).
3275 = Type ERROR
3275_UT = An error occurred in the lift and grip unit.
3275_ST = The lift ramp could not be written.
3275_UH = Note down the error number and inform the service department.
3275_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3276 = Type ERROR
3276_UT = An error occurred in the lift and grip unit.
3276_ST = Error while calculating lift ramp data.
3276_UH = Note down the error number and inform the service department.
3276_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3277 = Type ERROR
3277_UT = An error occurred in the lift and grip unit.
3277_ST = Moving the lift isn't possible because the flaps stays in the path.
3277_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3277_SH = Check the unload flaps, sensors, power supply and cable connections on the backplane.
3278 = Type ERROR
3278_UT = An error occurred in the lift and grip unit.
3278_ST = FPGA and Parameter Grip Mode do not match.
3278_UH = Note down the error number and inform the service department.
3278_SH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3279 = Type INFO
3279_UT = Any part of the covering isn't closed correctly or the emergency switch is activated.
3280 = Type WAITING
3280_UT = Exposed plate is keeping in recorder.
3280_ST = Exposed plate is keeping in recorder.
3280_UH = To eject the plate press the switch-off-button at the recorder for 2-3 seconds.
3280_SH = To eject the plate press the switch-off-button at the recorder for 2-3 seconds.
3281 = Type INFO
3281_UT = The service switch bypasses the safety loop.
3286 = Type ERROR
3286_UT = Unexpected plate on table detected. Init recorder or error correction not possible.
3286_ST = Unexpected plate on table detected. Init recorder or error correction not possible.
3286_UH = Remove plate from table and execute error correction.
3286_SH = Remove plate from table and execute error correction.
3287 = Type ERROR
3287_UT = An error occurred in the lift and grip unit.
3287_ST = The lift stepping motor cannot find it's zero position.
3287_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3287_SH = Check the power supply, and cables to the FLR-Board.
3288 = Type INFO
3288_UT = An internal hardware error occurred. One or more fans at the plate-table don't work.
3288_ST = One or more of the guide fans at the plate-table don't work.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 27 of 49
3288_RT = Table fan 1 is not running.
3288_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3288_SH = Check the cable connections on the backplane.
3289 = Type INFO
3289_UT = An internal hardware error occurred. One or more fans at the plate-table don't work.
3289_ST = One or more of the guide fans at the plate-table don't work.
3289_RT = Table fan 2 is not running.
3289_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3289_SH = Check the cable connections on the backplane.
3296 = Type CRITICAL
3296_UT = Voltage failure !
3296_ST = The negative analog 5 V failed !
3296_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3296_SH = Check the backplane.
3297 = Type CRITICAL
3297_UT = Voltage failure !
3297_ST = The positive analog 5 V failed !
3297_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3297_SH = Check the backplane.
3298 = Type CRITICAL
3298_UT = Voltage failure !
3298_ST = The positive 5 V failed !
3298_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3298_SH = Check the power supply.
3299 = Type CRITICAL
3299_UT = Voltage failure !
3299_ST = The positive 36 V failed !
3299_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3299_SH = Check the power supply.
3300 = Type CRITICAL
3300_UT = Voltage failure !
3300_ST = The positive 15 V failed!
3300_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3300_SH = Check the backplane.
3301 = Type CRITICAL
3301_UT = Voltage failure !
3301_ST = The positive 42 V failed!
3301_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3301_SH = Check the power supply.
3302 = Type CRITICAL
3302_UT = Voltage failure !
3302_ST = The positive 7.5 V failed !
3302_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3302_SH = Check the backplane.
3303 = Type CRITICAL
3303_UT = Voltage failure !
3303_ST = The positive 24 V failed !
3303_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3303_SH = Check the safety loop and the power supply (24V).
3304 = Type CRITICAL
3304_UT = Voltage failure !
3304_ST = The positive analog 24 V failed !
3304_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 28 of 49
3304_SH = Check the power supply.
3305 = Type CRITICAL
3305_UT = Voltage failure !
3305_ST = The positive 3.3 V failed !
3305_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3305_SH = Check the power supply.
3306 = Type CRITICAL
3306_UT = Voltage failure !
3306_ST = The positive 2.5 V failed !
3306_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3306_SH = Check the DSC board.
3307 = Type ERROR
3307_UT = Safety loop check failed !
3307_ST = Safety loop check failed. Check the Logfile for further information.
3307_UH = Check all safety loop relevant switches.
3307_SH = Check the complete safety loop (cabling, switches, relays ... ).
3309 = Type ERROR
3309_UT = An error occurred in the material base.
3309_ST = The requested material does not exist.
3309_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3309_SH = Check the material parameter whether the requested material exits.
3310 = Type ERROR
3310_UT = An error occurred at material transport.
3310_ST = The plate center unit does not left the light barrier.
3310_UH = Execute error correction. If the error still occurs, note down the error number and inform the service.
3310_SH = Check plate table, table motor and sensors. Check table static parameters.
3310_RH = Check Parameter 21866, 21868, 21871.
3311 = Type ERROR
3311_UT = An error occurred at material transport.
3311_ST = An unexpected motor stop from stepper counter at plate centering.
3311_UH = Execute error correction. If the error still occurs, note down the error number and inform the service.
3311_SH = Check plate table, table motor and sensors. Check table static parameters.
3312 = Type ERROR
3312_UT = An error occurred in the air supply unit.
3312_ST = The air pressure did not reach the required minimum.
3312_UH = Note down the error number and inform the service department.
3312_SH = Check the air supply unit and the AirPressureMin parameter.
3315 = Type INFO
3315_UT = The aging of the laser diode has accelerated!.
3315_ST = Too few exposure time has elapsed since the last automatic increase of the bias current setvalue. Nevertheless the
bias current setvalue will be increased.
3315_UH = If this Info appears often, note down the message number and inform the service department.
3315_SH = If this Info appears often, the end of life of the laser diode may reach in the near future.
3316 = Type INFO
3316_UT = The end of lifetime of the laser diode is approaching!.
3316_ST = The nominal maximum limit of the total current of the laser diode has been reached.
3316_UH = Note down the error number and inform the service department.
3316_SH = Note down the error number and inform the service department.
3317 = Type CRITICAL
3317_UT = An error occurred in the air supply unit.
3317_ST = The mirror air pressure is above stop-limit.
3317_UH = Switch off the recorder and restart it. If the error still occurs, note down the error number and notify the service
department.
3317_SH = Check the air supply unit. The bypass valve has to be recalibrate.
3318 = Type INFO
3318_UT = An error occurred in the air supply unit.
3318_ST = The mirror air pressure is above info-limit.
3318_UH = Note down the error number and inform the service department.
3318_SH = Check the air supply unit, and adjust the air pressure system and the bypass valve.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 29 of 49
3325 = Type ERROR
3325_UT = An error occurred in the material base. The preferred shaft has not been specified.
3325_ST = The preferred shaft is used in case a material shall be loaded which gets no link from any shaft.
3325_UH = Set the preferred shaft with the grafical user interface.
3325_SH = The preferred shaft is specified by the material parameter 93. This parameter has to be set to the pid of the preferred
shaft.
3326 = Type ERROR
3326_UT = An error occurred in the material base.
3326_ST = The name of the material that is send with the command request material is invalid.
3327 = Type WAITING
3327_UT = Remove Plate from table. Plate is exposed.
3327_ST = Remove Plate from table.
3327_RT = SVI - USR_REMOVE_EXPOSED_PLATE_FROM_TABLE
3328 = Type WAITING
3328_UT = Remove Plate from table. Plate is unexposed.
3328_ST = Remove plate from manual tray.
3328_RT = SVI - USR_REMOVE_UNEXPOSED_PLATE_FROM_TABLE
3329 = Type WAITING
3329_UT = OLP program change necessary.
3329_ST = OLP program change necessary.
3329_RT = SVI - USR_OLP_PROGRAM_CHANGE_NECESSARY
3329_UH = The specified OLP program for the current plate in process differs from the program of the last processed plate. Select
the correct OLP program.
3329_SH = The OLP program check can be disabled in the GUI (Device-Options-Material).
3913 = Type ERROR
3913_UT = Autoloader error state detected.
3913_ST = Autoloader error state detected.
3913_RT = SVI - ERR_MC_AUTOLOADER_ERROR_STATE_DETECTED
3913_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
3913_SH = Send an error report and the logfile to the respective R&D department.
3914 = Type ERROR
3914_UT = Internal software or parameter error.
3914_ST = Syntax error in debug configuration.
3914_RT = SVI - ERR_DBG_BOOT_CONF_SYNTAX
3914_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
3915 = Type INFO
3915_UT = The Emergency Switch is activated.
3915_RT = SVI - INF_EMERGENCY_SWITCH_ACTIVATED
3916 = Type ERROR
3916_UT = The boot sequence failed. Please reboot the system.
3916_ST = The boot sequence failed. Please reboot the system.
3916_RT = SVI - ERR_RECORDER_INIT_FAILED
3916_UH = Reboot the system. If the message still occurs, note down the error number and inform the service.
3916_SH = Connect a terminal to the recorder and capture the output to a file. Reboot the system. Send an error report and the
capture file to the respective R&D department.
4001 = Type ERROR
4001_UT = Internal software or parameter error.
4001_ST = Syntax error in debug configuration.
4001_RT = SVI - ERR_DBG_BOOT_CONF_SYNTAX
4001_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4002 = Type ERROR
4002_UT = Execution error - A general STOP occurred.
4002_ST = A general BREAK occurred.
4002_RT = SVI - ERR_GENERAL_BREAK
4002_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4003 = Type ERROR
4003_UT = Internal error - sensor not recognized.
4003_ST = A sensor in the device does not respond.
4003_RT = SVI - ERR_SENSOR_REQUEST_FAILED
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 30 of 49
4003_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4004 = Type ERROR
4004_UT = Internal error - setting a sensor failed.
4004_ST = Writing to a sensor failed.
4004_RT = SVI - ERR_SENSOR_SET_FAILED
4004_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4005 = Type ERROR
4005_UT = Internal error - actuator not recognized.
4005_ST = An actuator in the device does not respond.
4005_RT = SVI - ERR_ACTOR_REQUEST_FAILED
4005_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4006 = Type ERROR
4006_UT = Internal error - setting an actuator failed.
4006_ST = Writing to an actuator failed.
4006_RT = SVI - ERR_ACTOR_SET_FAILED
4006_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4007 = Type ERROR
4007_UT = Error checking the Cassette/Waste safety loop.
4007_ST = There is a problem with the safety loop of the Cassette / Waste section. Checking it failed.
4007_RT = SVI - ERR_SAFETY_LOOP_CHECK_FAILED
4007_UH = Restart the recorder and the autoloader. If the message still occurs, note down the error number and inform the
service.
4007_SH = See the log file for further details.
4008 = Type ERROR
4008_UT = Invalid Autoloader machine type set.
4008_RT = SVI - ERR_UNKNOWN_MACHINE_TYPE
4008_UH = Note down the error number and inform the service.
4008_SH = Specify the correct machine type (see manual) and restart the system.
4009 = Type INFO
4009_UT = Any part of the covering isn't closed correctly.
4009_RT = ORL - INF_SAFETY_LOOP_OPEN_PANELLING
4010 = Type CRITICAL
4010_UT = The safety loop was at least briefly interrupted.
4010_RT = ORL - ERR_SAFETY_LOOP_OPEN
4010_UH = Close all covers of the machine and execute an error correction.
4010_SH = Check the safety loop switches and the emergency switch.
4011 = Type INFO
4011_UT = The service switch bypasses the safety loop.
4011_RT = ORL - INF_SERVICE_LOOP_IS_CLOSED
4012 = Type ERROR
4012_UT = Internal system error.
4012_ST = Error using operating system function.
4012_RT = Error taking semaphore.
4012_UH = Switch off the system and restart it. If the error still occurs, note down the error number and notify the service
department.
4012_SH = Switch off the system and restart it. If the error still occurs, note down the error number and notify the service
department.
4013 = Type ERROR
4013_UT = Error checking the cover safety loop.
4013_ST = There is a problem with the safety loop of the cover section. Checking it failed.
4013_RT = SVI - ERR_SAFETY_LOOP_CHECK_FAILED
4013_UH = Close all covers careful. Restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4013_SH = See the log file for further details.
4014 = Type ERROR
4014_UT = Runtime error.
4014_ST = Internal software error.
4014_RT = SVI - ERR_MC_UNEXPECTED_DAL_RESPONSE
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 31 of 49
4014_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4014_SH = Get the logfile and contact the development department.
4015 = Type INFO
4015_UT = The Emergency Switch is activated.
4015_RT = SVI - INF_EMERGENCY_SWITCH_ACTIVATED
4016 = Type ERROR
4016_UT = The boot sequence failed. Please reboot the system.
4016_ST = The boot sequence failed. Please reboot the system.
4016_RT = SVI - ERR_RECORDER_INIT_FAILED
4016_UH = Reboot the system. If the message still occurs, note down the error number and inform the service.
4016_SH = Connect a terminal to the recorder and capture the output to a file. Reboot the system. Send an error report and the
capture file to the respective R&D department.
4100 = Type ERROR
4100_UT = Error separating a plate.
4100_RT = WBR - ERR_SEP_GLOBAL_ABLAUF_ERROR
4100_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4101 = Type ERROR
4101_UT = Error initializing the shutter.
4101_ST = Unable to access the shutter init sensor.
4101_RT = WBR - ERR_SEP_JAL_INIT_SENSOR_NOT_REACHED
4101_UH = Verify that there is a cassette and that the waste container is closed. Remove the problem or restart the recorder and
the autoloader. If the message still occurs, note down the error number and inform the service.
4101_SH = Check whether the sensor and / or the shutter motor are working.
4102 = Type ERROR
4102_UT = Error initializing the shutter.
4102_ST = Unable to quit the shutter init sensor.
4102_RT = WBR - ERR_SEP_JAL_INIT_SENSOR_NOT_LEFT
4102_UH = Verify that there is a cassette and that the waste container is closed. Manually remove all plates in the system.
Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4102_SH = Check whether the sensor and / or the shutter motor are working.
4103 = Type ERROR
4103_UT = Error moving the shutter.
4103_ST = Unable to move the shutter into waste position.
4103_RT = WBR - ERR_SEP_JAL_WASTE_POS_NOT_REACHED
4103_UH = Verify that there is a cassette and that the waste container is closed. Manually remove all plates in the system.
Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4103_SH = Check whether the shutter motor is working. Make sure that the safety loop is closed.
4104 = Type ERROR
4104_UT = Error moving the shutter.
4104_ST = The shutter failed to get to the material transfer position.
4104_RT = WBR - ERR_SEP_JAL_MAT_TAKE_POS_NOT_REACHED
4104_UH = Verify that there is a cassette and that the waste container is closed. Manually remove all plates in the system.
Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4104_SH = Check whether the shutter motor is working. Make sure that the safety loop is closed.
4105 = Type ERROR
4105_UT = Error polling a load table plate sensor.
4105_ST = Load table plate sensor on the suction cart not found.
4105_RT = WBR - ERR_SEP_JAL_LTB_PLATE_SENSOR_NOT_FOUND
4105_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4105_SH = Check whether the sensor and / or the shutter motor are working.
4106 = Type ERROR
4106_UT = Error separating.
4106_ST = Plate lost while separating or during transport to the entry of the load table plate. The plate did not arrive at the relevant
sensor.
4106_RT = WBR - ERR_SEP_JAL_LTB_PLATE_LOST
4106_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4106_SH = Check whether the sensor and / or the shutter motor are working.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 32 of 49
4107 = Type ERROR
4107_UT = Error placing the plate on the load table plate.
4107_ST = Plate lost during transport to the load table plate, the table plate sensor on the suction cart fails to detect the plate at
the end of the transfer process.
4107_RT = WBR - ERR_SEP_JAL_LTB_PLATE_SENSOR_AGAIN
4107_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4107_SH = Check whether the sensor and the suction cart (motors, suction pads) are working.
4108 = Type ERROR
4108_UT = Error moving the shutter.
4108_ST = Separator exit sensor not left when transporting the plate to the load table plate.
4108_RT = WBR - ERR_SEP_JAL_EXIT_SENSOR_NOT_LEFT
4108_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4108_SH = Check whether the sensor and the suction cart (motors, suction pads) are working.
4109 = Type ERROR
4109_UT = Paper sheet lost when separating.
4109_ST = When depositing the paper sheet, the vacuum shows that the sheet was lost during transfer into the waste container.
4109_RT = WBR - ERR_SEP_JAL_PAPER_TO_WASTE_LOST
4109_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4109_SH = Check whether the suction bar is working.
4110 = Type ERROR
4110_UT = Error initializing the stripper unit.
4110_ST = Stripper unit did not arrive at the init position during initialization.
4110_RT = WBR - ERR_SEP_STRIPPER_INIT_SENSOR_NOT_REACHED
4110_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4110_SH = Check whether the sensor and / or the stripper motor are working.
4111 = Type ERROR
4111_UT = Error initializing the stripper unit.
4111_ST = Unable to quit the init sensor of the stripper unit.
4111_RT = WBR - ERR_SEP_STRIPPER_INIT_SENSOR_NOT_LEFT
4111_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4111_SH = Check whether the sensor and / or the stripper motor are working.
4112 = Type ERROR
4112_UT = Error moving the stripper unit into working position.
4112_ST = Unable to quit the parking sensor of the stripper unit.
4112_RT = WBR - ERR_SEP_STRIPPER_NO_WORK_POS
4112_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4112_SH = Check whether the sensor and / or the stripper motor are working.
4113 = Type ERROR
4113_UT = Error moving the stripper unit.
4113_ST = Unable to get to the parking sensor of the stripper unit.
4113_RT = WBR - ERR_SEP_STRIPPER_NO_PARK_POS
4113_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4113_SH = Check whether the sensor and / or the stripper motor are working.
4115 = Type ERROR
4115_UT = Moving the stripper unit into the parking position caused an error several times.
4115_ST = Moving the stripper unit into the parking position caused an error several times.
4115_RT = WBR - ERR_SEP_STRIPPER_PARK_INIT_COUNT
4115_UH = Note down the error number and inform the service! Then remove the problem or restart the recorder and the
autoloader.
4115_SH = The stripper unit arrived at the parking position only after initializing the unit. This error is reported only after it has
occurred several times. Indicative of the stripper unit moving with difficulty, for example.
4116 = Type ERROR
4116_UT = A sensor was not reached while the stripper unit was moving to its park position.
4116_ST = The light barrier of the park sensor was not detected while the stripper unit was moving to its park position.
4116_RT = WBR - ERR_SEP_STRIPPER_PARK_SENS_NOT_REACHED
4116_UH = Eliminate the error or restart the recorder and Autoloader. If the error continues to occur, note the error number and
inform the service personnel.
4116_SH = The clamp must be closed for the stripper unit to move. Check that the light barrier (park sensor) functions. Check the
unit for sluggishness or whether the paddles are caught.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 33 of 49
4117 = Type ERROR
4117_UT = A sensor was not reached during initialization of the stripper unit.
4117_ST = The light barrier of the park sensor was not detected during initialization of the stripper unit.
4117_RT = WBR - ERR_SEP_STRIPPER_HOME_SENS_NOT_REACHED
4117_UH = Eliminate the error or restart the recorder and Autoloader. If the error continues to occur, note the error number and
inform the service personnel.
4117_SH = The clamp must be closed for the stripper unit to move. Check that the light barrier (park sensor) functions. Check the
unit for sluggishness or whether the paddles are caught.
4118 = Type ERROR
4118_UT = A sensor was not reached during normalization of the shutter.
4118_ST = The zero light barrier was not detected during normalization of the shutter.
4118_RT = WBR - ERR_SEP_JAL_NORM_SENS_NOT_REACHED
4118_UH = Note the error number and inform the service personnel!! Then eliminate the error or restart the recorder and
Autoloader.
4118_SH = The safety switch triggered by the cassette or waste container must be closed before the shutter can move. Check that
the zero light barrier functions. Check the unit for sluggishness and whether the clearance of the drive gear wheels is
too big.
4119 = Type ERROR
4119_UT = A sensor was not reached during initialization of the shutter.
4119_ST = The zero light barrier was not detected during initialization of the shutter.
4119_RT = WBR - ERR_SEP_JAL_HOME_SENS_NOT_REACHED
4119_UH = Note the error number and inform the service personnel!! Then eliminate the error or restart the recorder and
Autoloader.
4119_SH = The safety switch triggered by the cassette or waste container must be closed before the shutter can move. Check that
the zero light barrier functions. Check the unit for sluggishness and whether the clearance of the drive gear wheels is
too big.
4120 = Type ERROR
4120_UT = Error initializing the cassette shutter.
4120_ST = Cassette shutter motor did not arrive at the init position during initialization.
4120_RT = WBR - ERR_SEP_ROLLER_INIT_SENSOR_NOT_REACHED
4120_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4120_SH = Check whether the sensor and the cassette shutter motor are working.
4121 = Type ERROR
4121_UT = Error initializing the cassette shutter.
4121_ST = Unable to quit the init position when initializing the cassette shutter motor.
4121_RT = WBR - ERR_SEP_ROLLER_INIT_SENSOR_NOT_LEFT
4121_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4121_SH = Check whether the sensor and the cassette shutter motor are working.
4122 = Type ERROR
4122_UT = Error while preparing cassette shade drive for taking a new cassette.
4122_ST = Sensor could not detect the requested phase 1 during the specified number of attempts during initialization of the
cassette shade drive.
4122_RT = WBR - ERR_SEP_ROLLER_COUPLE_POS_NO_STEP_1
4122_UH = Eliminate the error or restart the recorder and Autoloader. If the error continues to occur, note the error number and
inform the service personnel.
4122_SH = Check functioning of the sensor and cassette shade drive. Check the installation position of the sensor.
4123 = Type ERROR
4123_UT = Error while preparing cassette shade drive for taking a new cassette.
4123_ST = Sensor could not detect the requested phase 2 during the specified number of attempts during initialization of the
cassette shade drive.
4123_RT = WBR - ERR_SEP_ROLLER_COUPLE_POS_NO_STEP_2
4123_UH = Eliminate the error or restart the recorder and Autoloader. If the error continues to occur, note the error number and
inform the service personnel.
4123_SH = Check functioning of the sensor and cassette shade drive. Check the installation position of the sensor.
4124 = Type ERROR
4124_UT = A sensor was not reached during initialization of the cassette shade drive.
4124_ST = The light barrier of the close sensor was not detected during initialization of the cassette shade drive.
4124_RT = WBR - ERR_SEP_ROLLER_HOME_SENS_NOT_REACHED
4124_UH = Eliminate the error or restart the recorder and Autoloader. If the error continues to occur, note the error number and
inform the service personnel.
4124_SH = The cassette must be locked (compressed air on) for the cassette shade drive to move. Check the cassette shade for
sluggishness.
4130 = Type ERROR
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 34 of 49
4130_UT = Error moving the suck bar.
4130_ST = The suck bar did not arrive in its new position during the expected time.
4130_RT = WBR - ERR_SEP_SUCKBAR_UP_TIMEOUT
4130_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4130_SH = Check the compressed air and the sensor.
4133 = Type ERROR
4133_UT = Error lowering the suck bar.
4133_ST = The suck bar is not at its bottom position as expected.
4133_RT = WBR - ERR_SEP_SUCK_BAR_NOT_DOWN
4133_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4133_SH = Check the compressed air, the connectors, and the relevant sensor elements.
4134 = Type ERROR
4134_UT = Error moving the suck bar.
4134_ST = The suck bar is not at the middle position as expected.
4134_RT = WBR - ERR_SEP_SUCK_BAR_NOT_MID
4134_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4134_SH = Check the compressed air, the connectors, and the relevant sensor elements.
4135 = Type ERROR
4135_UT = Error lifting the suck bar.
4135_ST = The suck bar is not at the top position as expected.
4135_RT = WBR - ERR_SEP_SUCK_BAR_NOT_UP
4135_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4135_SH = Check the compressed air, the connectors, and the relevant sensor elements.
4136 = Type ERROR
4136_UT = Error moving the suck bar.
4136_ST = The suck bar does not move.
4136_RT = WBR - ERR_SEP_SUCK_BAR_NOT_MOVED
4136_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4136_SH = Check the compressed air, the connectors, and the relevant sensor elements.
4137 = Type ERROR
4137_UT = Error setting the suck bar parameters.
4137_ST = A command to the suck bar returned an invalid command.
4137_RT = WBR - ERR_SEP_SUCK_BAR_ERROR
4137_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4138 = Type ERROR
4138_UT = While separating, double sheet error Paper under plate occurred several times without a plate being present.
4138_ST = While separating, double sheet error Paper under plate occurred several times without a plate being present.
4138_RT = WBR - ERR_SEP_MEDIA_EXIST_SENSOR_ERROR
4138_UH = Note down the error number and inform the service! Then remove the problem or restart the recorder and the
autoloader.
4138_SH = Double sheet Paper under plate found, but no plate is present. This error is reported only after it has occurred several
times. Indicative of a malfunction of the metal sensor on the suction bar.
4139 = Type ERROR
4139_UT = A piece of paper, located on the Jalousie, couldn't fix by the suck bar
4139_ST = A piece of Paper couldn't move from the suck bar to the Jalousie suction bar.
4139_RT = WBR - ERR_SEP_PAPER_LOST_AT_SUCKBAR
4139_UH = Please remove the paper manually from the cassette!! Then execute an error correction or restart the recorder and the
autoloader
4140 = Type ERROR
4140_UT = Error setting the separator ejector parameters.
4140_ST = Invalid command encountered when enabling the ejector's blowing function.
4140_RT = WBR - ERR_SEP_EJECTOR_BLOW_ERROR
4140_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4141 = Type ERROR
4141_UT = Error setting the separator ejector parameters.
4141_ST = Invalid command encountered when enabling the ejector's suction function.
4141_RT = WBR - ERR_SEP_EJECTOR_SUCK_ERROR
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 35 of 49
4141_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4141_SH = Check the compressed air, the connectors, and the relevant actuator elements.
4142 = Type ERROR
4142_UT = Error setting the separator ejector parameters.
4142_ST = Invalid command encountered when actuating the compressed air supply of the ejector's suck bar.
4142_RT = WBR - ERR_SEP_EJECTOR_SUCK_BAR_ACTIVE_ERROR
4142_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4143 = Type ERROR
4143_UT = Error setting the separator ejector parameters.
4143_ST = Invalid command encountered when actuating the compressed air supply of the ejector's suction bar.
4143_RT = WBR - ERR_SEP_EJECTOR_SUCKSTRIP_ACTIVE_ERROR
4143_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4144 = Type ERROR
4144_UT = Vacuum error signaled by vacuum sensor. Unable to suck and hold the material or material lost.
4144_ST = The vacuum sensor of the separator detected an insufficient vacuum.
4144_RT = WBR - ERR_SEP_EJECTOR_NO_VACUUM_SENSE2
4144_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4144_SH = Check the compressed air, the hoses, and the connectors if this error occurs more frequently.
4152 = Type ERROR
4152_UT = Error setting the double sheet sensor parameters.
4152_ST = Invalid command encountered when selecting the double sheet sensor.
4152_RT = WBR - ERR_SEP_MEDIA_LAYERS_ACTIVE_ERROR
4152_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4153 = Type ERROR
4153_UT = No or not enough compressed air.
4153_ST = Poll of compressed air status result: no compressed air.
4153_RT = WBR - ERR_SEP_MEDIA_NO_PRESSURE
4153_UH = Check the compressed air supply. Remove the problem or restart the recorder and the autoloader. If the message still
occurs, note down the error number and inform the service.
4153_SH = Check the compressed air supply and or its settings (pressure gauge, actuators).
4154 = Type ERROR
4154_UT = Error separating. A double sheet detected cannot be separated because the suction bar is carrying material already.
4154_RT = WBR - ERR_SEP_DOUBLE_SHEET_SUCKBAR_IN_USE
4154_UH = Remove the material from the separator exit. Remove the problem or restart the recorder and the autoloader. If the
message still occurs, note down the error number and inform the service.
4155 = Type ERROR
4155_UT = A double sheet detected on the jalousie. The material could not be separated.
4155_ST = The double sheet must be removed manually by hand.
4155_RT = WBR - ERR_SEP_DOUBLE_SHEET_ON_JAL_HELP_BY_USER
4155_UH = Please remove the material sheet manually by hand. Execute an Error Correction or restart the system. Check the
material in the cassette - it shouldn't be tight at the side-guides and the paper and plates must be aligned with the
leading edge of the cassette.
4156 = Type ERROR
4156_UT = A double sheet was detected on the Jalousie. The material couldn't be split.
4156_ST = The double sheet couldn't fix by the suck bar - it must be removed by hand.
4156_RT = WBR - ERR_SEP_DOUBLE_SHEET_OUT_OF_RANGE
4156_UH = Please remove the material by hand. Check the material in the cassette regarding the borders (the material should not
be very close to the borders) and regarding the leading edge (plate and paper should be justify at the leading border).
4157 = Type ERROR
4157_UT = A double sheet was detected on the Jalousie. The material couldn't be split.
4157_ST = The double sheet couldn't fix by the suck bar - it must be removed by hand.
4157_RT = WBR - ERR_SEP_DOUBLE_SHEET_POS_OUT_OF_RANGE
4157_UH = Please remove the material by hand. Check the material in the cassette regarding the borders (the material should not
be very close to the borders) and regarding the leading edge (plate and paper should be justify at the leading border).
4161 = Type ERROR
4161_UT = Tray empty. No material on the active tray.
4161_ST = No material found when reading the tray fill level.
4161_RT = WBR - ERR_SEP_CASS_NO_MATERIAL
4161_UH = Take out the tray and put in a full tray with the requested material.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 36 of 49
4161_SH = Check whether the Media Exist sensor on the suck bar is working.
4162 = Type ERROR
4162_UT = A detected double sheet on the Jalousie couldn't move to the Load Table
4162_ST = A double sheet wasn't detected from the exit-sensor of the separator.
4162_RT = WBR - ERR_SEP_NO_SUCCESS_SEPARATE_MAT_ON_JAL
4162_UH = Please remove the material by hand. Afterwards execute an error correction or reboot the system. Check the material
in the cassette regarding the borders (the material should not be very close to the borders) and regarding the leading
edge (plate and paper should be justify at the leading border)
4163 = Type ERROR
4163_UT = A double sheet was detected on the Jalousie. The material couldn't be split within several tries.
4163_ST = The double sheet couldn't be split within several tries - it must be removed by hand.
4163_RT = WBR - ERR_SEP_NO_SUCCESS_SEPARATE_MAT_FROM_JAL
4163_UH = Please remove the material by hand. Check the material in the cassette regarding the borders (the material should not
be very close to the borders) and regarding the leading edge (plate and paper should be justify at the leading border).
4164 = Type ERROR
4164_UT = While checking the material at the suction bar, an error with the vacuum occurred.
4164_RT = WBR - ERR_SEP_MATERIAL_LOST_AT_SUCKSTRIP
4164_UH = Please remove the material by hand. Afterwards execute an error correction or reboot the system.
4165 = Type ERROR
4165_UT = While sucking the paper with the suck bar, a vacuum error occurred.
4165_ST = There was no vacuum at the suction bar.
4165_RT = WBR - ERR_SEP_PAPER_LOST_AT_SUCKSTRIP
4165_UH = Please remove the paper by hand. Afterwards execute an error correction or reboot the system.
4165_SH = Check the position of the upper and lower suction bar in this case.
4166 = Type ERROR
4166_UT = The paper could not be removed, because the cassette was not open.
4166_RT = WBR - ERR_SEP_CASSETTE_CLOSED
4166_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4166_SH = Internal control error.
4167 = Type ERROR
4167_UT = While loading and locking the cassette an error occured inside the SCL.
4167_RT = WBR - ERR_SEP_CASS_LOCK_ERROR
4167_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4167_SH = Internal control error.
4171 = Type ERROR
4171_UT = Clamp jaw unit error.
4171_ST = Unable to close the clamp jaw.
4171_RT = WBR - ERR_SEP_CLAMP_JAW_NOT_CLOSED
4171_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4171_SH = Check the clamp jaw unit, the compressed air, and the sensor.
4172 = Type ERROR
4172_UT = Clamp jaw unit error.
4172_ST = Unable to open the clamp jaw unit - the unit will not release the plate.
4172_RT = WBR - ERR_SEP_CLAMP_JAW_NOT_OPENED
4172_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4172_SH = Check the clamp jaw unit, the compressed air, and the sensor.
4173 = Type ERROR
4173_UT = Error closing the clamp jaw unit.
4173_ST = Unable to close the clamp jaw unit during the expected time.
4173_RT = WBR - ERR_SEP_CLAMP_JAW_CLOSE_TIMEOUT
4173_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4173_SH = Check the clamp jaw unit, the compressed air, and the sensor.
4174 = Type ERROR
4174_UT = Error opening the clamp jaw unit.
4174_ST = Unable to open the clamp jaw unit during the expected time.
4174_RT = WBR - ERR_SEP_CLAMP_JAW_OPEN_TIMEOUT
4174_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4174_SH = Check the clamp jaw unit, the compressed air, and the sensor.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 37 of 49
4181 = Type INFO
4181_UT = No material found in the cassette.
4181_ST = No material was detected during check of cassette level.
4181_RT = WBR - INF_SEP_CASS_NO_MATERIAL
4181_UH = Unload the cassette and load one filled with the requested material.
4182 = Type INFO
4182_UT = Almost no material in the cassette.
4182_ST = A check of the cassette level detected only a few plates still in the cassette. The number has fallen below the set alert
level.
4182_RT = WBR - INF_SEP_CASS_NEARLY_NO_MATERIAL
4182_UH = Unload the cassette and load one filled with the requested material.
4183 = Type INFO
4183_UT = The waste container is full.
4183_ST = A check of the waste container level detected that the container is full.
4183_RT = WBR - INF_SEP_WASTE_FULL
4183_UH = Open the waste container, remove the paper and close the container again.
4184 = Type INFO
4184_UT = The waste container is almost full.
4184_ST = A check of the waste container level detected that the set alert level was exceeded.
4184_RT = WBR - INF_SEP_WASTE_NEARLY_FULL
4184_UH = Open the waste container, remove the paper and close the container again.
4190 = Type ERROR
4190_UT = Error setting the waste container parameters.
4190_ST = Invalid command encountered when opening / closing the waste container.
4190_RT = WBR - ERR_SEP_WASTE_ERROR
4190_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4191 = Type ERROR
4191_UT = Unable to open the waste container.
4191_ST = The waste container could not be opened because it was impossible to move the shutter into the specified position.
4191_RT = WBR - ERR_SEP_WASTE_UNABLE_TO_OPEN
4191_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4191_SH = Check the sensor and actuator elements of the waste container and the shutter drive, moving the shutter requires a
cartridge to be present.
4192 = Type ERROR
4192_UT = Waste container open.
4192_ST = Could not open the cassette because the waste container was not closed.
4192_RT = WBR - ERR_SEP_WASTE_NOT_CLOSED
4192_UH = Close the waste container. Eliminate the error or restart the recorder and Autoloader. If this message recurs, note the
error number and inform the service personnel.
4192_SH = Check the sensors and actuators of the waste container and the shutter drive. A cassette must be loaded before the
shutter can move.
4193 = Type ERROR
4193_UT = Vacuum error at the suction bar. Could not suck the material to the bar or the material was lost.
4193_ST = Vacuum sensor detected that the vacuum was too low when the suction bar of the separator was used.
4193_RT = WBR - ERR_SEP_MAT_AT_SUCKBAR_LOST
4193_UH = Eliminate the error or restart the recorder and Autoloader. If the error continues to occur, note the error number and
inform the service personnel.
4193_SH = If this occurs frequently, check the compressed air, hoses, connections and suction cups at the suction bar.
4194 = Type ERROR
4194_UT = Vacuum error after raising the suction bar. Could not suck the material to the bar or the material was lost.
4194_ST = Vacuum sensor detected that the vacuum was too low after raising the suction bar.
4194_RT = WBR - ERR_SEP_MAT_LIFT_AND_LOST
4194_UH = Eliminate the error or restart the recorder and Autoloader. If the error continues to occur, note the error number and
inform the service personnel.
4194_SH = If this occurs frequently, check the compressed air, hoses, connections and suction cups at the suction bar.
4195 = Type ERROR
4195_UT = Configuration error - unknown machine type.
4195_ST = Invalid machine type set.
4195_RT = WBR - ERR_SEP_UNKNOWN_MACHINE_TYPE
4195_UH = Specify the correct machine type in the autoloader and restart the system.
4196 = Type ERROR
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 38 of 49
4196_UT = Error separating.
4196_ST = Plate lost while separating or during transport to the entry of the load table plate. The plate did not arrive at the relevant
sensor.
4196_RT = WBR - ERR_SEP_PLATE_ON_JAL_LOST
4196_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4197 = Type ERROR
4197_UT = Error separating.
4197_ST = Material lost when lifting it out of the tray.
4197_RT = WBR - ERR_SEP_LIFT_MAT_FROM_CASS_AND_LOST
4197_UH = Remove the problem or restart the recorder and the autoloader. If the message still occurs, note down the error
number and inform the service.
4198 = Type ERROR
4198_UT = An error occurred during initialization or error handling. Material was found on the shutter.
4198_ST = Material was found on the shutter during initialization or error handling. The material is to be removed by the operator.
4198_RT = WBR - ERR_SEP_PLATE_ON_JAL_HELP_BY_USER
4198_UH = Please remove the material from the separator by hand. Then remove the problem or restart the recorder and the
autoloader. If the message still occurs, note down the error number and inform the service.
4201 = Type ERROR
4201_UT = Unable to determine the position of the load table plate.
4201_ST = Both load table plate position sensors output the same signal.
4201_RT = SVI - ERR_LTB_TABLE_POS
4201_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4201_SH = Check the sensor elements of the load table plate. Make sure that the sensor contacts are adjusted properly.
4202 = Type ERROR
4202_UT = Error moving the load table.
4202_ST = Timeout encountered when swivelling/moving the load table.
4202_RT = SVI - ERR_LTB_TABLE_MOVE_TIMEOUT
4202_UH = Check the air pressure. Execute an Error Correction or restart the system. If the message still occurs, note down the
error number and inform the service.
4202_SH = Check the compressed air, the connectors, and the relevant sensors.
4203 = Type ERROR
4203_UT = The load table fans are not working.
4203_RT = SVI - ERR_LTB_FAN_NOT_RUNNING
4203_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4203_SH = Check the cabling and connectors of the load table fans.
4204 = Type ERROR
4204_UT = Error moving the plate holder.
4204_ST = Timeout encountered when lifting/lowering the plate holder.
4204_RT = SVI - ERR_LTB_PLATE_HLD_MOVE_TIMEOUT
4204_UH = Check the compressed air. Execute an Error Correction or restart the system. If the message still occurs, note down
the error number and inform the service.
4204_SH = Check the compressed air, the connectors, and the adjustment of the relevant sensor.
4205 = Type ERROR
4205_UT = Error initializing the plate holder.
4205_ST = The plate holder did not move away from its init sensor.
4205_RT = SVI - ERR_LTB_PLDR_INIT_SENS_NOT_LEFT
4205_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4205_SH = Check whether the sensor and the plate holder motor are working.
4206 = Type ERROR
4206_UT = Error initializing the plate drive motor.
4206_ST = The plate holder did not move up to its init sensor.
4206_RT = SVI - ERR_LTB_PLDR_INIT_SENS_NOT_REACHED
4206_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4206_SH = Check whether the sensor and the plate holder motor are working.
4207 = Type ERROR
4207_UT = Error initializing the plate drive motor.
4207_ST = Initialization of the plate drive motor failed. Absolute positioning of the plate holder is not possible.
4207_RT = SVI - ERR_LTB_PLDR_NOT_INITIALIZED
4207_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 39 of 49
4208 = Type ERROR
4208_UT = No plate on the load table.
4208_ST = The procedure requires a plate but none has been detected.
4208_RT = SVI - ERR_LTB_NO_PLATE_ON_TAB
4208_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4208_SH = Check the position of the plate inside the system and very that the sensor in the plate holder is working.
4209 = Type ERROR
4209_UT = Error initializing the center unit.
4209_ST = The center unit did not move away from its init sensor.
4209_RT = SVI - ERR_LTB_CEDV_INIT_SENS_NOT_LEFT
4209_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4209_SH = Check whether the sensor and the center unit motor are working.
4210 = Type ERROR
4210_UT = Error initializing the center unit.
4210_ST = The center unit did not move up to its init sensor.
4210_RT = SVI - ERR_LTB_CEDV_INIT_SENS_NOT_REACHED
4210_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4210_SH = Check whether the sensor and the center unit motor are working.
4211 = Type ERROR
4211_UT = Material transport error.
4211_ST = Error transporting the plate from the load table to the conveyor.
4211_RT = SVI - ERR_LTB_UNLOAD_PLATE_TO_CON
4211_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4212 = Type ERROR
4212_UT = Plate not in the gripper.
4212_ST = The plate did not move up to the grip sensor.
4212_RT = SVI - ERR_LTB_CEDV_GRIP_SENS_NOT_REACHED
4212_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4212_SH = Check whether the grip sensor is working and the gripper position is correct.
4213 = Type ERROR
4213_UT = The width of the plate loaded is not as requested. The link to the active shaft was removed.
4213_ST = Wrong width of plate. See the log file for further details.
4213_RT = SVI - ERR_PLATE_WIDTH_DOES_NOT_MATCH
4213_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4214 = Type ERROR
4214_UT = Load table process error.
4214_ST = A signal expected from the load table holder sensor not received.
4214_RT = SVI - ERR_LTB_PLDR_HOLDER_SENS_INTR_NOT_DETECTED
4214_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4214_SH = Check whether the load table holder sensor is working.
4215 = Type ERROR
4215_UT = Error initializing the load table.
4215_ST = The states of the load table sensors have been checked. The result is an impossible combination.
4215_RT = SVI - ERR_LTB_SENS_ACTIVE_COMBINATION
4215_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4215_SH = Check whether the load table sensors are working correctly.
4226 = Type ERROR
4226_UT = Double sheet detected on load table during material transport to recorder.
4226_ST = Please remove the material manually by hand.
4226_RT = WBR - ERR_LTB_DOUBLE_SHEET_ON_TABLE_USER_HELP
4226_UH = Please remove the material manually by hand from load table. Execute an Error Correction or restart the system.
4227 = Type ERROR
4227_UT = The load table can not be moved, because material was detected between separator and load table.
4227_ST = Material was detected in light barrier of the separator. The material is to be removed by the operator before moving the
load table.
4227_RT = WBR - ERR_LTB_NO_MOVEMENT_SEP_EXIT_NOT_FREE
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 40 of 49
4227_UH = Please remove the material from the separator by hand. Execute an Error Correction or restart the system.
4301 = Type ERROR
4301_UT = Error moving the conveyor.
4301_ST = Timeout lifting/lowering the conveyor table.
4301_RT = SVI - ERR_CON_MOVER_TIMEOUT
4301_UH = Check the compressed air. Execute an Error Correction or restart the system. If the message still occurs, note down
the error number and inform the service.
4301_SH = Check the compressed air, the connectors, and the relevant sensors.
4302 = Type ERROR
4302_UT = Error initializing the conveyor roller motor.
4302_ST = Initialization of the conveyor roller motor failed.
4302_RT = SVI - ERR_CON_CORO_NOT_NORMED
4302_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4302_SH = Check whether the conveyor entry sensor is working.
4303 = Type ERROR
4303_UT = Error transporting the plate from the conveyor to the load table.
4303_ST = Plate transport from the conveyor to the load table is not possible. The plate has left the range of the entry sensor
already.
4303_RT = SVI - ERR_CON_UNLOAD_NOT_POSSIBLE
4303_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4304 = Type ERROR
4304_UT = Error centering the plate on the conveyor.
4304_ST = Unable to fully load the plate onto the conveyor. The conveyor entry sensor is not free.
4304_RT = SVI - ERR_CON_ENTRY_SENS_NOT_FREE
4304_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4304_SH = Check the drive of the conveyor rollers and the two sensors on the conveyor.
4305 = Type ERROR
4305_UT = No plate on the conveyor.
4305_ST = The procedure requires a plate but none has been detected.
4305_RT = SVI - ERR_CON_NO_PLATE_ON_TAB
4305_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4306 = Type ERROR
4306_UT = Configuration error - no valid assembly position of the online processor.
4306_ST = Assembly position of the online processor wrong or not specified.
4306_RT = SVI - ERR_CON_OLP_MOUNT_POS_UNKNOWN
4306_UH = Note down the error number and inform the service.
4306_SH = Specify the correct assembly side of the online processor in the recorder and autoloader system configuration and
restart the system.
4307 = Type ERROR
4307_UT = Error centering the plate on the conveyor.
4307_ST = Conveyor center sensor not enabled.
4307_RT = SVI - ERR_CON_PLATE_ON_TAB_NOT_REACHED
4307_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4307_SH = Check the drive of the conveyor rollers and the two sensors on the conveyor.
4308 = Type ERROR
4308_UT = Error initializing the conveyor slider.
4308_ST = The conveyor slider did not move away from its init sensor.
4308_RT = SVI - ERR_CON_CVSL_HOME_SENS_NOT_LEFT
4308_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4308_SH = Check the conveyor slider motor and the relevant sensor.
4309 = Type ERROR
4309_UT = Error initializing the conveyor slider.
4309_ST = The conveyor slider did not move up to its init sensor.
4309_RT = SVI - ERR_CON_CVSL_HOME_SENS_NOT_REACHED
4309_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4309_SH = Check the conveyor slider motor and the relevant sensor.
4310 = Type ERROR
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 41 of 49
4310_UT = Error initializing the conveyor slider.
4310_ST = Initialization of the conveyor slider motor failed.
4310_RT = SVI - ERR_CON_COSL_NOT_INITIALIZED
4310_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4311 = Type ERROR
4311_UT = Error unloading the plate.
4311_ST = Signal expected from the conveyor entry sensor not received.
4311_RT = SVI - ERR_CON_ENTRY_SENS_INTR_NOT_DETECTED
4311_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4311_SH = Check whether the conveyor entry sensor is working.
4312 = Type ERROR
4312_UT = Conveyor process error.
4312_ST = Signal expected from the conveyor slider init sensor not received.
4312_RT = SVI - ERR_CON_HOME_SENS_INTR_NOT_DETECTED
4312_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4312_SH = Check whether the initialization sensor of the conveyor slider is working.
4313 = Type ERROR
4313_UT = Error actuating the online processor.
4313_ST = No ON signal of the online processor.
4313_RT = SVI - ERR_CON_NO_OLP_ON_SIGNAL
4313_UH = Make sure that the online processor is on and ready and execute an error correction. If the message still occurs, note
down the error number and inform the service.
4313_SH = Check whether the OLP and the HW interface are working.
4314 = Type ERROR
4314_UT = Error actuating the online processor.
4314_ST = No connect signal of the online processor.
4314_RT = SVI - ERR_CON_NO_OLP_CONNECT_SIGNAL
4314_UH = Make sure that the online processor is connected, on and ready. Execute an Error Correction or restart the system. If
the message still occurs, note down the error number and inform the service.
4314_SH = Check whether the OLP and the HW interface are working.
4315 = Type ERROR
4315_UT = Configuration error - wrong online processor interface set.
4315_ST = The set online processor interface is unknown.
4315_RT = SVI - ERR_CON_OLP_IF_UNKNOWN
4315_UH = Note down the error number and inform the service.
4315_SH = Specify the correct online processor interface in the recorder and autoloader system configuration and restart the
system.
4316 = Type ERROR
4316_UT = Error unloading the plate.
4316_ST = Error centering the plate on the conveyor. The computed correction exceeds the maximum.
4316_RT = SVI - ERR_CON_CENTER_PLATE_DISTANCE
4316_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4316_SH = Check whether the conveyor entry sensor is working. See the log file for further details.
4317 = Type ERROR
4317_UT = Error unloading the plate.
4317_ST = Signal expected from the conveyor exit sensor not received.
4317_RT = SVI - ERR_CON_EXIT_SENS_INTR_NOT_DETECTED
4317_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4317_SH = Check whether the conveyor exit sensor is working.
4318 = Type ERROR
4318_UT = Error unloading the plate.
4318_ST = Signal expected from the conveyor center sensor not received.
4318_RT = SVI - ERR_CON_PLATE_ON_TAB_INTR_NOT_DETECTED
4318_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4318_SH = Check whether the conveyor center sensor is working.
4319 = Type ERROR
4319_UT = Error initializing the conveyor.
4319_ST = The states of the conveyor sensors have been checked. The result is an impossible combination.
4319_RT = SVI - ERR_CON_SENS_ACTIVE_COMBINATION
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 42 of 49
4319_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4319_SH = Check whether the conveyor sensors are working correctly.
4320 = Type ERROR
4320_UT = Error centering the plate on the conveyor.
4320_ST = Unable to readjust the plate onto the conveyor. The plate is expected on the entry sensor but isn't there.
4320_RT = SVI - ERR_CON_ENTRY_SENS_NOT_FREE
4320_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4320_SH = Check the drive of the conveyor rollers and the entry sensor on the conveyor.
4401 = Type ERROR
4401_UT = An error occurred while swinging out the cassette drive.
4401_ST = One of the two cassette drives did not reach its swing-out position in the allotted time.
4401_RT = WBR - ERR_MCL_CASSDRV_SWIVEL_OUT_TIMEOUT
4401_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4401_SH = Check the compressed air and the sensor.
4402 = Type ERROR
4402_UT = An error occurred while swinging in the cassette drive.
4402_ST = One of the two cassette drives did not leave its swing-out position in the allotted time.
4402_RT = WBR - ERR_MCL_CASSDRV_NOT_SWIVELED_IN
4402_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4402_SH = Check the compressed air and the sensor.
4403 = Type ERROR
4403_UT = An error occurred during the cassette drive setup.
4403_ST = An invalid command for the cassette drive was detected.
4403_RT = WBR - ERR_MCL_CASSDRV_SWIVEL_ERROR
4403_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4404 = Type ERROR
4404_UT = An error occurred while evaluating the current cassette position.
4404_ST = The sensors for the horizontal cassette position returned an invalid position.
4404_RT = WBR - ERR_MCL_CASSDRV_POSITION_ERROR
4404_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4404_SH = Check the functioning of the horizontal position sensors and the elevator position.
4405 = Type ERROR
4405_UT = No cassette was detected at the MCL exit when conveying a cassette from the SCL to the MCL.
4405_ST = The exit sensor of the MCL did not detect a cassette.
4405_RT = WBR - ERR_MCL_CASSDRV_CASS_NOT_IN_EXIT
4405_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4405_SH = Check the functioning of the horizontal position sensors and the elevator position.
4406 = Type ERROR
4406_UT = No cassette was detected at the MCL entry when loading a cassette.
4406_ST = The cassette drive sensor (perhaps the entry sensor as well) did not detect a cassette.
4406_RT = WBR - ERR_MCL_CASSDRV_CASS_NOT_AT_POS_ENTRY_DRV
4406_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4406_SH = Check the functioning of the horizontal position sensors and the elevator position.
4407 = Type ERROR
4407_UT = No fully loaded cassette was detected while unloading a cassette from the MCL.
4407_RT = WBR - ERR_MCL_CASSDRV_CASS_NOT_LOADED
4407_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4407_SH = Check the functioning of the horizontal position sensors, the elevator position and the state of the cassette lock.
4408 = Type ERROR
4408_UT = A cassette could not be positioned correctly while loading it from the SCL.
4408_ST = The specified number of attempts to position the cassette was exceeded.
4408_RT = WBR - ERR_MCL_CASSDRV_POS_COMPLETE_COUNT_EXIT
4408_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4408_SH = Check the functioning of the horizontal position sensors, the elevator position and the functioning of the cassette drive.
The cassette might not have been fully closed (plate jam) and got caught in the SCL exit as a result.
4409 = Type ERROR
4409_UT = A cassette could not be positioned correctly while loading it from the trolley.
4409_ST = The specified number of attempts to position the cassette was exceeded.
4409_RT = WBR - ERR_MCL_CASSDRV_POS_COMPLETE_COUNT_ENTRY
4409_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4409_SH = Check the functioning of the horizontal position sensors, the elevator position and the functioning of the cassette drive.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 43 of 49
4410 = Type ERROR
4410_UT = Error closing the inlet door.
4410_ST = The inlet door did not reach the position in the allotted time.
4410_RT = WBR - ERR_MCL_INLET_CLOSE_TIMEOUT
4410_UH = Check the MCL entry and remove the cassette causing the error. Correct the error or restart the system. If the
message still occurs, note down the error number and inform the service.
4410_SH = Check the compressed air, the sensors and the MCL entry.
4411 = Type ERROR
4411_UT = Error opening the inlet door.
4411_ST = The inlet door did not reach the position in the allotted time.
4411_RT = WBR - ERR_MCL_INLET_OPEN_TIMEOUT
4411_UH = Check the MCL entry and remove the cassette causing the error. Correct the error or restart the system. If the
message still occurs, note down the error number and inform the service.
4411_SH = Check the compressed air, the sensors and the MCL entry.
4412 = Type ERROR
4412_UT = An error occurred while evaluating the current inlet door position.
4412_ST = The sensors for the inlet door position returned an invalid position.
4412_RT = WBR - ERR_MCL_INLET_ERROR
4412_UH = Check the MCL entry and remove the cassette causing the error. Correct the error or restart the system. If the
message still occurs, note down the error number and inform the service.
4412_SH = Check the compressed air, the sensors and the MCL entry.
4413 = Type ERROR
4413_UT = An error occurred during the setup of the inlet door drive.
4413_ST = An invalid command for the inlet door drive was detected.
4413_RT = WBR - ERR_MCL_INLET_UNKNOWN_COMMAND
4413_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4414 = Type ERROR
4414_UT = The inlet door was not open before a cassette was unloaded to the trolley.
4414_RT = WBR - ERR_MCL_INLET_NOT_OPENED
4414_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4414_SH = Check the compressed air, the sensors and the MCL entry.
4415 = Type ERROR
4415_UT = The inlet door was not closed before the elevator moved.
4415_RT = WBR - ERR_MCL_INLET_NOT_CLOSED
4415_UH = Check the MCL entry and remove the cassette causing the error. Correct the error or restart the system. If the
message still occurs, note down the error number and inform the service.
4415_SH = Check the sensors and the MCL entry.
4420 = Type ERROR
4420_UT = Error initializing the elevator.
4420_ST = The elevator init sensor was not reached.
4420_RT = WBR - ERR_MCL_ELV_INIT_SENSOR_NOT_REACHED
4420_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4420_SH = Check whether the sensors and the elevator drive are working.
4421 = Type ERROR
4421_UT = Error initializing the elevator.
4421_ST = The elevator init sensor was not left.
4421_RT = WBR - ERR_MCL_ELV_INIT_SENSOR_NOT_LEFT
4421_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4421_SH = Check whether the sensors and the elevator drive are working.
4422 = Type ERROR
4422_UT = An error occurred while evaluating the current elevator position.
4422_ST = The sensors for the vertical cassette position detected an invalid position.
4422_RT = WBR - ERR_MCL_ELV_UNKNOWN_CASE_STATE
4422_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4422_SH = Check whether the sensors and the elevator drive are working.
4423 = Type ERROR
4423_UT = Failed to find cause of aborted movement after elevator or cassette drive finished moving.
4423_ST = The cause was an undefined event.
4423_RT = WBR - ERR_MCL_UNKNOWN_EVENT_DETECTED
4423_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4424 = Type ERROR
4424_UT = The elevator or cassette drive did not finish moving by reaching a sensor.
4424_RT = WBR - ERR_MCL_NO_EVENT_DETECTED
4424_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 44 of 49
4425 = Type ERROR
4425_UT = An error occurred while moving the elevator.
4425_ST = The error bit of the elevator motor is active.
4425_RT = WBR - ERR_MCL_ELV_STEPPER_MOTOR_FAULT
4425_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4425_SH = Check the drive for voltage supply and that the elevator drive is working.
4426 = Type ERROR
4426_UT = A safety error occurred before the elevator moved.
4426_ST = One of the two cassette drives is not swung out.
4426_RT = WBR - ERR_MCL_ELV_SECURITY_SWIVEL_OUT
4426_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4426_SH = Check whether the swivel drives of the horizontal cassette drives and their sensors are working.
4427 = Type ERROR
4427_UT = A safety error occurred before the elevator moved.
4427_ST = The cassette in the SCL was not locked.
4427_RT = WBR - ERR_MCL_ELV_SECURITY_SCL_CASS
4427_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4427_SH = Check the compressed air and the cassette drive sensors in the SCL.
4428 = Type ERROR
4428_UT = An error occurred while evaluating the current elevator position.
4428_ST = The sensors for the vertical cassette position returned an invalid position.
4428_RT = WBR - ERR_MCL_ELV_CASE_STATE_ERROR
4428_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4428_SH = Check whether the sensors of the elevator drive are working.
4429 = Type ERROR
4429_UT = An error occurred during the elevator setup.
4429_ST = An invalid command for the elevator was detected.
4429_RT = WBR - ERR_MCL_ELV_CASE_DEST_ERROR
4429_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4440 = Type ERROR
4440_UT = No fully loaded cassette was detected before unloading a cassette from the MCL to the SCL or the trolley.
4440_RT = WBR - ERR_MCL_CASS_NOT_IN_POS_AT_START
4440_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4440_SH = Check the sensors.
4441 = Type ERROR
4441_UT = No fully loaded cassette was detected after loading a cassette from the SCL or the trolley to the MCL.
4441_RT = WBR - ERR_MCL_CASS_NOT_IN_POS_AT_END
4441_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4441_SH = Check the sensors.
4442 = Type ERROR
4442_UT = No cassette was detected at the MCL entry sensor before loading a cassette from the SCL to the MCL.
4442_RT = WBR - ERR_MCL_CASS_NOT_IN_EXIT_AT_START
4442_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4442_SH = Check the sensors.
4443 = Type ERROR
4443_UT = No cassette was detected at the MCL exit sensor after unloading a cassette from the MCL to the SCL.
4443_RT = WBR - ERR_MCL_CASS_NOT_IN_EXIT_AT_END
4443_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4443_SH = Check the sensors.
4444 = Type ERROR
4444_UT = No cassette was detected at the MCL entry sensor before loading a cassette from the trolley to the MCL.
4444_RT = WBR - ERR_MCL_CASS_NOT_IN_ENTRY_AT_START
4444_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4444_SH = Check the sensors.
4445 = Type ERROR
4445_UT = No cassette was detected at the MCL entry sensor after unloading a cassette from the MCL to the trolley.
4445_RT = WBR - ERR_MCL_CASS_NOT_IN_ENTRY_AT_END
4445_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4446 = Type ERROR
4446_UT = A cassette was detected to be not fully loaded to its position before the elevator moved.
4446_RT = WBR - ERR_MCL_CASS_POS_COMPLETE_ERROR
4446_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4446_SH = Check the sensors and the elevator position.
4447 = Type ERROR
4447_UT = The cassette is not in valid position.
4447_RT = WBR - ERR_MCL_CASS_POSITION_ERROR
4447_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4448 = Type ERROR
4448_UT = No trolley was found in front of the MCL before unloading a cassette from the MCL.
4448_RT = WBR - ERR_MCL_MISSING_TROLLEY
4448_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4449 = Type ERROR
4449_UT = A cassette was detected in the SCL before unloading a cassette from the MCL to the SCL.
4449_RT = WBR - ERR_MCL_SCL_CASS_DETECTED
4449_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4450 = Type ERROR
4450_UT = The elevator could not be moved or movement had to be stopped too soon because the cassette drive was no longer
swung out.
4450_RT = WBR - ERR_MCL_CASS_DRIVE_NOT_SWIVELD_OUT
4450_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4451 = Type ERROR
4451_UT = An error occurred, at least one safety relay of the MCL is open.
4451_RT = WBR - ERR_MCL_SAFETY_RELAIS_OPEN
4451_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4460 = Type INFO
4460_UT = Movement of elevator started, duration approximately 90 sec.
4460_RT = WBR - INF_MCL_ELV_MOVE_THREE_CASES
4461 = Type INFO
4461_UT = Movement of elevator started, duration approximately 60 sec.
4461_RT = WBR - INF_MCL_ELV_MOVE_TWO_CASES
4462 = Type INFO
4462_UT = Movement of elevator started, duration approximately 30 sec.
4462_RT = WBR - INF_MCL_ELV_MOVE_ONE_CASE
4500 = Type WAITING
4500_UT = No tray with the requested material.
4500_ST = Further processing will be paused until a tray with the requested material has been put in.
4500_RT = ORL - USR_MC_SEP_INSERT_CASS_REQUIRED
4500_UH = Please insert a tray with the requested material. The job will be automatically resumed afterwards.
4501 = Type WAITING
4501_UT = The waste container is open.
4501_ST = Further processing will be paused until the waste container has been closed.
4501_RT = ORL - USR_MC_SEP_CLOSE_WASTE_REQUIRED
4501_UH = Please close the waste container. The job will be automatically resumed afterwards.
4502 = Type WAITING
4502_UT = The load table is not free. The system may be waiting for a plate to be moved on into the online processor.
4502_ST = Further processing will be paused until the load table is free again.
4502_RT = ORL - USR_MC_TAB_TABLE_NOT_FREE
4502_UH = The pause will be automatically finished as soon as the plate has been removed from the load table. Manual
manipulation will be required only if this message does not disappear after a while.
4502_SH = Check the online processor. The job will be automatically resumed when the plate has been moved away from the load
table.
4503 = Type WAITING
4503_UT = The conveyor is not free. The system may be waiting for a plate to be moved on into the online processor.
4503_ST = Further processing will be paused until the conveyor is free again.
4503_RT = ORL - USR_MC_CON_CONVEYOR_NOT_FREE
4503_UH = The pause will be automatically finished as soon as the plate has been removed from the conveyor. Manual
manipulation will be required only if this message does not disappear after a while.
4503_SH = Check the online processor. The job will be automatically resumed when the plate has been moved away from the
conveyor.
4504 = Type WAITING
4504_UT = The trolley is not in loading/unloading position.
4504_ST = Further processing will be paused until the trolley is in the correct position.
4504_RT = ORL - USR_MC_SEP_TROLEY_REQUIRED
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 46 of 49
4504_UH = Please move the trolley into the correct loading/unloading position. The job will be automatically resumed afterwards.
4505 = Type WAITING
4505_UT = Online processor not ready - no connect signal.
4505_ST = Further processing will be paused until a connect signal has been received from the online processor.
4505_RT = ORL - USR_MC_CON_OLP_NOT_CONNECTED
4505_UH = Make sure that the online processor is connected and on. The pause will be automatically finished as soon as a
connect signal has been received from the online processor. Manual manipulation will be required only if this message
does not disappear after a while.
4505_SH = Check the online processor. The job will be automatically resumed when the connect signal has been received.
4506 = Type WAITING
4506_UT = The online processor is off.
4506_ST = Further processing will be paused until the online processor is on and has sent a ready signal.
4506_RT = ORL - USR_MC_CON_OLP_IS_OFF
4506_UH = Make sure that the online processor is on. The pause will be automatically finished as soon as the online processor
has been switched on. Manual manipulation will be required only if this message does not disappear after a while.
4506_SH = Check the online processor. The job will be automatically resumed when the ready signal has been received.
4507 = Type WAITING
4507_UT = The online processor is busy.
4507_ST = Further processing will be paused until the state of the online processor has changed from Busy to Not Busy.
4507_RT = ORL - USR_MC_CON_OLP_IS_BUSY
4507_UH = The pause will be automatically finished as soon as the online processor is no longer busy. Manual manipulation will
be required only if this message does not disappear after a while.
4507_SH = Check the online processor. The job will be automatically resumed when the status of the online processor has
changed from Busy to Not Busy.
4508 = Type WAITING
4508_UT = The paper container is full.
4508_ST = Further processing will be paused until the paper container has been opened and emptied.
4508_RT = ORL - USR_MC_SEP_EMPTY_WASTE_REQUIRED
4508_UH = The pause will be automatically finished when you close the paper container again.
4509 = Type WAITING
4509_UT = Tray empty.
4509_ST = Further processing will be paused until the tray has been removed, filled with material and put back in.
4509_RT = ORL - USR_MC_SEP_CASS_IS_EMPTY
4509_UH = Please insert a tray with the requested material. The job will be automatically resumed afterwards.
4510 = Type WAITING
4510_UT = No or not enough compressed air.
4510_ST = Further processing will be paused until the pressure level has reached the required value.
4510_RT = SVI - USR_MC_PRESSURE_REQUIRED
4510_UH = Check the compressed air supply. Assure that the pressure level has the required value
4511 = Type WAITING
4511_UT = Remove the cassette.
4511_ST = Further processing will be paused until the cassette has been removed.
4511_RT = SVI - USR_MC_REMOVE_CASS_REQUIRED
4511_UH = Please pull the cassette onto the trolley completely.
4512 = Type WAITING
4512_UT = Insert required plate to bypass.
4512_ST = Insert required plate to bypass.
4512_RT = SVI - USR_MC_INSERT_PLATE_BYPASS_REQUIRED
4512_UH = Insert required plate to bypass. The job will be automatically resumed afterwards.
4513 = Type WAITING
4513_UT = Remove plate from bypass. Plate width is not as requested.
4513_ST = Remove plate from bypass.
4513_RT = SVI - USR_MC_REMOVE_PLATE_BYPASS_REQUIRED
4513_UH = The plate inserted does not match the requested plate. The job will be automatically resumed as soon as the plate has
been removed.
4520 = Type INFO
4520_UT = Shaft data inconsistency detected. Rescan initiated (approx. 120 sec.).
4520_RT = SVI - INF_MC_SCAN_SHAFTS
4530 = Type ERROR
4530_UT = Error executing comand.
4530_ST = The DAL command is not implemented.
4530_RT = SVI - ERR_MC_DAL_CMD_NOT_IMPLEMENTED
4530_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4530_SH = Send an error report and the log file to the responsible R&D department
4531 = Type ERROR
4531_UT = Error executing command.
4531_ST = The DAL command was rejected.
4531_RT = SVI - ERR_MC_DAL_CMD_REJECTED
4531_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4531_SH = Send an error report and the logfile to the respective R&D department.
4532 = Type ERROR
4532_UT = Error loading/unloading a cassette.
4532_ST = Loading/unloading the cassette to the specified tray was impossible as the tray already contained a cassette.
4532_RT = SVI - ERR_MC_DEST_SHAFT_CONTAINS_A_CASS
4532_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4532_SH = Send an error report and the logfile to the respective R&D department.
4533 = Type ERROR
4533_UT = Error loading/unloading a cassette.
4533_ST = The specified tray number is out of range.
4533_RT = SVI - ERR_MC_SHAFT_NUMBER_OUT_OF_RANGE
4533_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4533_SH = Send an error report and the logfile to the respective R&D department.
4534 = Type ERROR
4534_UT = Error loading/unloading a cassette.
4534_ST = The specified tray type is incorrect.
4534_RT = SVI - ERR_MC_SHAFT_TYPE_ERROR
4534_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4534_SH = Send an error report and the logfile to the respective R&D department.
4535 = Type ERROR
4535_UT = Error loading/unloading a cassette.
4535_ST = The state of the specified tray is incorrect.
4535_RT = SVI - ERR_MC_SHAFT_STATE_ERROR
4535_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4535_SH = Send an error report and the logfile to the respective R&D department.
4536 = Type ERROR
4536_UT = Initialization failed.
4536_ST = The initialization loop exceeded the maximum.
4536_RT = SVI - ERR_MC_INIT_LOOP_FAILED
4536_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4536_SH = Send an error report and the logfile to the respective R&D department.
4537 = Type ERROR
4537_UT = Error Correction failed.
4537_ST = The error correction loop exceeded the maximum.
4537_RT = SVI - ERR_MC_ERROR_CORRECTION_LOOP_FAILED
4537_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4537_SH = Send an error report and the logfile to the respective R&D department.
4538 = Type ERROR
4538_UT = Shut down failed.
4538_ST = The shutdown loop exceeded the maximum.
4538_RT = SVI - ERR_MC_SHUTDOWN_LOOP_FAILED
4538_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4538_SH = Send an error report and the logfile to the respective R&D department.
4988 = Type ERROR
4988_UT = An error was detected in the horizontal drive of the MCL.
4988_ST = The elevator's motor control detected an error and switched itself off.
4988_RT = WBR - ERR_MCL_STEPPER_MOTOR_FAULT
4988_UH = Correct the error or restart the system. If the message still occurs, note down the error number and inform the service.
4988_SH = Check the motor cable screw fittings, its screening box and the broad ribbon cables between MCL and SCL.
Prosetter-AL
Messages
Staack, Thomas/E3/Phone.: 3877
date: 18.01.2005 Error-List-EN.doc / Page 48 of 49
4989 = Type ERROR
4989_UT = Error initializing a motor.
4989_ST = Unable to quit the home sensor.
4989_RT = WBR - ERR_RAMP_INIT_SENSOR_NOT_LEFT
4989_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4989_SH = Check whether the sensor and / or the motor are working.
4990 = Type ERROR
4990_UT = Error initializing a motor.
4990_ST = Expected home sensor not found at the target position.
4990_RT = WBR - ERR_RAMP_INIT_SENSOR_NOT_REACHED
4990_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4990_SH = Check whether the sensor and / or the motor are working.
4991 = Type ERROR
4991_UT = Error controlling a motor.
4991_ST = Expected sensor not found at the target position.
4991_RT = WBR - ERR_RAMP_SENSOR_NOT_FOUND
4991_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4992 = Type ERROR
4992_UT = Error controlling a motor.
4992_ST = Invalid parameter found when computing the data for stepper motor actuation.
4992_RT = WBR - ERR_RAMP_TYPE_FAILURE
4992_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4993 = Type ERROR
4993_UT = Error controlling a motor.
4993_ST = No actuation data found when starting the stepper motor.
4993_RT = WBR - ERR_RAMP_NO_STEPS
4993_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4994 = Type ERROR
4994_UT = Error controlling a motor.
4994_ST = Insufficiently larger memory range found when computing the data for stepper motor actuation.
4994_RT = WBR - ERR_RAMP_MAX_INDEX
4994_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4995 = Type ERROR
4995_UT = Error controlling a motor.
4995_ST = Absolute motor positioning not possible, the motor is to be initialized first.
4995_RT = WBR - ERR_RAMP_NO_ABS_MODE
4995_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4996 = Type ERROR
4996_UT = Error controlling a motor.
4996_ST = Timeout actuating the stepper motor.
4996_RT = WBR - ERR_RAMP_TIMEOUT
4996_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4997 = Type ERROR
4997_UT = Error controlling a motor.
4997_ST = Invalid minimum frequency for actuating the stepper motor.
4997_RT = WBR - ERR_RAMP_MIN_FREQ
4997_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4998 = Type ERROR
4998_UT = Error controlling a motor.
4998_ST = Invalid parameter found when computing the data for stepper motor actuation.
4998_RT = WBR - ERR_RAMP_PARAM
4998_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
4999 = Type ERROR
4999_UT = Error controlling a motor.
4999_ST = Error computing the data for actuating the stepper motor.
4999_RT = WBR - ERR_RAMP_CALC_FAILED
4999_UH = Execute an Error Correction or restart the system. If the message still occurs, note down the error number and inform
the service.
|